Decimal Display | - Top Display: Five Digits (0 to 99999), 0.7″ (0.05 ft) high, 7-segment, automatic lead zero blanking. Bottom Display: Seven
- Characters, 0.4″ (0.03 ft) high, 14-segment, automatic lead zero blanking.
- Symbols: Total, grand total, high alarm, low alarm, SafeTouch button sleep mode/disable, password lock.
|
Feet & Inches Display | - Top Display: 0.60″ (0.05 ft) high, 0 to 399 FT, 11 and 15/16 IN, 7-segment, programmable 1/16 or 1/8 fraction display.
- Bottom Display: Seven Characters, 0.4″ (0.03 ft) high, 14-segment, 7-digits.
- Tank Level Indicator: 20-segments, F (Full) and E (Empty).
- Alarm Indication: High and low alarm
- Backlight: White
|
Display Assignment | - Top and Bottom Display: Process Variables (PV); Alternating PV and Units, Tag and PV, or Tag, PV, and Units; Pulse Input
- Rate, Total, or Grand Total with Alternating Tag.
- Units and tags are independent for each PV, pulse input rate, total, and total.
Note:On feet and inches display models, the top display is used only for level Modbus process variables or math channels. |
Backlight | White LED, 10-sec auto-off when battery-powered. Backlight deactivated below temperature ~ -20°C (-4°F) |
Alarm Indication | Flashing display plus HI/LO (alarm) or SET indicators. |
Scan and Update Rate | - Ambient > -20°C (-4°F): Modbus PV scan rate programmable from 2 to 99 seconds per PV. Tag and units programmable for 1 to 5-second alternation. Pulse input variables update 1/second. Rate update is dependent on gate settings.
- Ambient < -20°C (-4°F): All Modbus scan, alternating units and tags, and pulse input variables update/10 seconds minimum.
|
Under Range | - Upper Display: Decimal display flashes -9999. The level display flashes to 399 FT, 11 and 15/16 IN
- Lower Display: Flashes -999999
|
OverRange | - Upper Display: Decimal display flashes 99999
- The level display flashes to 399FT 1115/16 IN
- Lower Display: Flashes 9999999
|
Programming Method | Four SafeTouch through-window buttons when the cover is installed. Four internal push buttons when the cover is removed. |
Recalibration | Calibrated at the factory to read frequency in Hz. No recalibration is required. |
Input Power | 9-30 VDC, 38 mA max. 2.2 W |
Password Menu | Three programmable password selections can be used for the following: restrict modification of settings, prevent resetting the total or grand total without the password, or permanently lock out the ability to change or reset the grand total or any grand total-related settings(making a non-resettable grand total).
- Pass: Restricts modifications of programmed settings to require re-entering the password to make changes.
- Pass T: Restricts the reset of the total to require re-entering the password. Disables the manual mode reset contact.
- Pass GT: Restricts the reset of grand total to require re-entering the password. May enable a non-resettable grand total
- and permanent lockout of grand total-related settings with a specific password.
|
Mounting | May be mounted directly to the conduit. Two slotted flanges for wall mounting or NPS 1-1/2" to 2-1/2" or DN 0.13 ft to 0.21 ft pipe mounting. |
Display Orientation | The display may be mounted at 90° increments up to 270° from default orientation. |
Overall Dimensions | 5.67″ x 5.25″ x 4.18″ (0.47 ft x 0.43 ft x 0.34 ft) (W x H x D) |
Weight | 1.65 lbs (26.4 oz, .75 kg) |