Standards |
Conformity to standards | UL |
Certificates and Declaration - Safety |
UL file number | E317092 |
Technical Characteristics |
Control operator | RTSE |
Number of poles | 3 |
Rated current [A] | 260 |
Technical Characteristics - Connection terminals |
Max. connection section / AWG | 600MCM / 2 X 250MCM |
Min. connection section / AWG | #4/2 X 1/0 |
Technical Characteristics - Environmental |
Operating temperature | -4 ... +122°F / -20 ... +50°C |
Storage temperature | -40 ... +158°F / -40 ...+70°C |
Technical Characteristics - Mechanical |
Endurance (number of operating cycles) | 6050 |
Technical Characteristics - Power supply |
Power supply / Supply voltage VAC 50/60 Hz | 208-277 VAC ± 20% |
Technical Characteristics - Short-circuit capacity |
Auxiliary contacts / Electrical characteristics | AC300 |
Operation voltage 2 P - 3/4 P | 240/600 |
Rated operational current / 240 VAC resistive load | 260 |
Rated operational current / 240 VAC “Total System” | 260 |
Rated operational current / 480 VAC resistive load | 260 |
Rated operational current / 480 VAC “Total System | 260 |
Rated operational current / 600 VAC resistive load | 260 |
Rated operational current / 600 VAC “Total System” | 200 |
Rated operational current / 600 VAC resistive load | 200 |
Short circuit rating at 600 VAC with “Any Breaker” / Short circuit capacity [ms] | 50 |
Short circuit rating at 600 VAC with “Any Breaker” / Short circuit rating [kA] | 14 |
Short circuit rating at 600 VAC [kA] | 65 |
Type of fuse | J |
Technical Characteristics - Switching time |
Switching time / Duration of electrical blackout | 0.6 |
Switching time / I to 0 or 0 to II | 0.85 |
Switching time / I to II or II to I | 1.3 |
ETIM - Electrical characteristics |
Max. rated operation voltage Ue AC [V] | 600 |
Rated operating voltage [V] | 240..600 |
Rated permanent current Iu [A] | 260 |
Rated short-time withstand current lcw [kA] | 14 |
Conditioned rated short-circuit current Iq [kA] | 65 |
Number of poles | 3 |
ETIM - Mechanical characteristics |
Suitable for floor mounting | No |
Suitable for front mounting 4-hole | No |
Suitable for front mounting centre | No |
Suitable for distribution board installation | No |
Suitable for intermediate mounting | Yes |
Colour control element | Other |
Degree of protection (IP), front side | IP20 |
ETIM - Technical features |
Version as main switch | Yes |
Version as maintenance-/service switch | Yes |
Version as safety switch | Yes |
Version as emergency stop installation | No |
Version as reversing switch | Yes |
Number of switches | 2 |
Number of auxiliary contacts as normally open contact | 3 |
Motor drive integrated | Yes |
Device construction | Built-in device fixed built-in technique |
Type of control element | Other |
Interlockable | Yes |
Type of electrical connection of main circuit | Bolt connection |
Logistics |
Weight of the packing unit | 17 |
Length of the packing unit | 0.42 |
Width of the packing unit | 0.48 |
Depth of the packing unit | 0.5 |
Product Details |
Country of origin | FR |
Length of the product unit | 0.26 |
Width of the product unit | 0.377 |
Depth of the product unit | 0.3205 |
Weight | 9 |
Classification |
UNSPSC | 39122205 |
ETIM Class | EC000216 |
IGCC | 5177 |