Pipe Sizes | 2" |
Flanges | 150 lb. ANSI Pattern |
Pressure | 150 psi (10.3 bar) line pressure |
Temperature |
Operating | 10° to 140° F (-12° to 60° C) |
Storage | -40° to 158° F (-40° to 70° C) |
Accuracy | ±0.75% of reading on iMAG 4700p and 4700r (±1.0% iMAG 4700), ±0.025% of full-scale flow from low flow cutoff to maxi. flow rate of 10 m/sec |
Low Flow Cutof | 0.5% of maximum flow rate |
Material |
Body | Welded steel, epoxy-coated |
Liner | Polyurethane/Noryl® |
Electronics Housing | Powder-coated diecast aluminum |
Electrodes | 316 stainless steel |
Display |
Type | 128x64 dot-matrix LCD |
Digits | 5 Digit Rate | 8 Digit Total |
Units | Rate Volume Units- Gallons
- Liters
- Barrels(42 gal)
- Cubic Feet
- Cubic Meters
- Million Gallons²
- Mega Liters²
- Imperial Gallons
- Million Imperial Gallons²
Rate Time Units | Total Volume Units- Gallons
- Gallons x 10
- Gallons x 100
- Gallons x 1000
- Million Gallons
- Liters
- Kilo Liters
- Mega Liters
- Barrels (42 gal)
- Cubic Meters
- Cubic Meters x 1000
- Cubic Feet
- Cubic Feet x 100
- Cubic Feet x 1000
- Second Foot Day
- Million Cubic Feet
- Acre Feet
- Acre Inches
- Imperial Gallons
- Imperial Gallons x 1000
- Million Imperial Gallons
- Fluid Ounces
|
Bidirectional | Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total³ |
Power |
DC Power | 9-36 Vdc at 250 mA max, 30 mA average |
Battery Backup (Not for use as primary power) | - DC powered units: One lithium 7.2V 'D' size battery pack, replaceable
- AC powered units: One 9V alkaline battery, replaceable
|
AC Power | 85-264Vac, 50/60Hz, 0.12A |
Battery | One lithium 7.2V 'D' size battery pack, replaceable |
Scaled Pulse Output |
Signal | Current sinking pulse, isolated, 36 Vdc at 10 mA max |
Pulse Rates | User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150 pulses/sec max |
Options |
4-20mA Current Loop | Isolated, passive, 24Vdc, 650 Ω maximum current loop |
High Speed Digital | Isolated, open collector, 24 Vdc |
Serial Communications | Isolated, asynchronous serial RS485, Modbus® RTU protocol |
Cable |
Power/Output Cable | 20ft (6m) standard length polyurethane jacketed cable - for power and outputs |
Remote Display Cable | 20ft (6m) standard length polyurethane jacketed cable - for connection between meter and remote display |
Conductivity | >20 microSiemens/cm |
Empty Pipe Detection | Hardware/software, conductivity-based |
Regulatory | (EN 61326), 2"-12" certified to NSF/ANSI standard 61 60°C (140°F) |
Environmental | NEMA 6P, IP68 (10ft (3m) depth, continuously) |