Input |
DC Input Voltage Range | 10.5 - 16.3 VDC (± 0.3 VDC) |
DC Input Current at Rated Load | 300A |
DC Input Current at No Load | < 1.1A |
Output |
AC Output Voltage | 115 VAC (± 5 VAC) |
AC Output Frequency | 60 Hz (± 1 Hz) |
AC Output in Inverter Mode |
Output Voltage | 100 - 120 VAC (User selectable) ; Default: 120 VAC |
Output Frequency | 45 - 65 Hz (User Selectable) ; Default: 60Hz |
Type & Output Wave Form | High Frequency Type ; Pure Sine Wave |
Total Harmonic Distortion of Output WaveForm | < 2% |
Continuous Output Power | 1200W |
Surge Output Power | 2000W |
Peak Efficiency | > 90% |
Neutral Isolation | - Neutral bonded to chassis ground when Inverter is supplying the Load
- Neutral isolated from Chassis Ground when Grid is supplying the Load
|
AC Output in Bypass Mode |
Output Voltage | Same as external AC Input source |
Type of Output WaveForm | Same as external AC Input source |
THD of Output WaveForm | Same as external AC Input source |
Continuous Output Power | 1200W Continuous (Protected by 15A AC Input breaker) |
Rating of Transfer Relay | 16A |
Transfer Relay Switching Time | < 8ms |
Transfer Type | Synchronized or Unsynchronized (User selectable) |
Neutral Isolation | Neutral and Chassis Ground are isolated through internal relay |
DC/AC Input |
Nominal DC Input Voltage | 48 VDC |
DC Input Voltage Range | 40 - 60 VDC |
DC Input No Load Current | < 0.5A |
AC Input from Grid/Generator | - Voltage: Programmed value of inverter Output Voltage (100 - 120 VAC) ± 10%
- Default: 120 VAC ±10%
- Frequency: 50/60 Hz
|
Display |
LCD | Alphanumeric: 2 lines x 16 characters each |
LEDS | 4 LEDS: AC GRID ; INVERTER ; BYPASS ; Alarm |
Local Control & Monitoring |
Mode and Parameter Setup | Through Menus displayed on the LCD screen |
Monitoring Operating Status | Through LCD screen and 4 LEDs |
Remote Control & Monitoring |
Parameter Setup and Monitoring Using USB / RS-232 | Through computer screen using ACII coded commands |
Monitoring Using Ethernet / SNMP | - Through computer’s Web Browser and Ethernet connection
- E-mail notification of faults and alarms
- Notification of faults and alarms through Ethernet / SNMP Trap Messaging
|
Wired on/off Control Through Terminals Marked ENB (High), ENB (Low) and GND | To switch ON:- External + 20 to 60VDC fed to ENB and GND (< 6mA)
- Short ENB and GND
- Battery Positive fed to ENB
|
Wired Signalling | - Signaling of faults and alarms through SPDT relay contact switching (no Voltage)
- Relay contact rating: 240 VAC, 16A
|