Flow measurement |
Measuring range | ±32 m/s |
Accuracy | - DN 50 mm: ±1.5 % f.s. for velocities > 0.3 m/s
- DN <50 mm: ±3.5 % f.s. for velocities > 0.3 m/s
- 0,001 m/s
|
Reproducibility | ±0.5 % of measured value |
PCE-TDS 200 MR SENSOR | Sensor pair |
Pipe diameter | DN 50 - 700 / 57 - 720 mm |
Temperature resistance | -30 - 160 °C |
Dimension | 45 x 30 x 30 mm |
PCE-TDS 200 L SENSOR |
Pipe diameter | DN 300 - 6000 mm |
Temperature resistance | -30 - 160 °C |
Dimension | 91 x 52 x 44 mm |
Measuring methodMedium | - Z, V, N, W
- water
- sea water
- oil
- crude oil
- methanol
- ethanol
- diesel
- petrol
- petroleum
- user defined
- (manual input of the sound velocity from the medium)
|
All liquids with an impurity | <5 % |
Pipe material | - copper CU
- steel FE
- stainless steel VA
- aluminium AL
- brass ME
- cast iron CI
- iron FE
- nickel NI
- titanium TI
- zink ZI
- acrylic AC
- polyethylene PE
- polypropylene PP
- polyvinyl chloride PVC
- nylon NY
- user defined
- (manual input of the transversal sound velocity of the pipe material)
|
Inner pipe lining | - no lining
- user defined
- epoxy resin
- rubber
- mortar
- polystyrene PS
- polyethylene PE
- polytetrafluoroethylene PTFE
- polyurethane PU
- polypropylene PP
- user defined
- (manual input of the transversal sound velocity of the pipe material)
|
Measurement parameters | flow velocity, volume flow and volume |
Units (dimensions) | mm, in |
Units (flow velocity) | m/s, ft/s |
Units (volume flow) | m, l, gal, igl, mgl, cf, bal, ib, ob |
Time specification | seconds, minutes, hours, days |
Units (volume) | m, l, gal, igl, mgl, cf, bal, ib, ob |
Temperature measurement |
Measuring range | Accuracy |
Type B: 600 - 1800 °C | Type B: ±(0.5 % + 3 °C) |
Type E: -100 - +900 °C | Type E: ±(0.4 % + 1 °C) |
Type J: -100 - 1150 °C | Type J: ±(0.4 % + 1 °C) |
Type K: -100 - +1370 °C | Type K: ±(0.4 % + 1 °C) |
Type N: -100 - + 1150 °C | Type N: ±(0.4 % + 1 °C) |
Type R: 0 - 1700 °C | Type R: ±(0.5 % + 3 °C) |
Type S: 0 - 1500 °C | Type S: ±(0.5 % + 3 °C) |
Type T: -100 - +400 °C | Type T: ±(0.4 % + 1 °C) |
Resolution | 0.1 °C |
Connectable thermocouples | B, E ,J ,K ,N ,R ,S ,T |
Measuring parameters | - flow rate, volume flow, volume, temperature
- Heat output and heat quantity
|
Units (temperature) | °C / °F |
Units (heat quantity) | K, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu |
Units (heat output) | W, kW, MW, J/h, kJ/h MJ/h, Btu/h, kBtu/h, MBtu/h |
Cost display | EUR, Pound, USD, Turkish Lira, Zloty, Yen |
Further specifications |
2.8" LCD | 2,8" LCD |
Menu | metrisch / imperial |
Menu languages | - German, English, French, Spanish, Italian, Dutch, Portuguese, Danish, Turkish, Polish, German
- Turkish, Polish, Russian, Chinese, Japanese
|
Operating and storage conditions | - Temperature: -20 - +65 °C
- Humidity: 10 - 95 % r. h., non-condensing
|
Data logger | 32 GB memory capacity / 10 million measuring points |
Unterface | - USB (for online measurement, readout of the internal memory
- memory and for recharging the battery)
|
Protection class | IP52 |
Power supply Internal | Internal: LiPo battery (3.7 V, 2500 mAh) |
| External: USB 5 VDC, 500 mA |
Operating time | approx. 10 h |
Dimensions | 165 x 85 x 32 mm |
Weight | 255 g |