Voltage (AC V) | - Measurement range: 10 V - 600 V (phase to neutral) / 10 V - 600 V (phase to neutral)
- Resolution: 0.1 V / 1 pF
- Accuracy: ± (0.5 % + 0.5 V) / (4 nF - 400 µF)
|
Current (AC A) | - Measurement range: 20 A / 200 A / 1200 A
- Resolution: 0.001 A (< 10 A) - 0.01 A (≥ 10 A) / 0.01 A (< 100 A) - 0.1 A (≥ 100 A) /" 0.1 A (< 1000 A) / 1 A (≥ 1000 A)
- Accuracy: ± (0.5 % + 0.1 V) / ± (0.5 % + 0.5 A) / ± (0.5 A + 5 A)
|
Active Power | - Measurement range: 0 KW - 9.999 KW / 10 KW - 99.99 KW / 100 KW - 999.9 KW / 1 MW - 9.999 MW
- Resolution: 0.001 KW / 0.01 KW / 0.1 KW / 0.001 MW
- Accuracy: ± (1 % + 0.008 KW) / ± (1 % + 0.008 KW) / ± (1 % + 0.8 KW) / ± (1 % + 0.008 MW)
|
Apparent Power | - Measurement range: 0 KVA - 9.999 KVA / 10 KVA - 99.99 KVA / 100 KVA - 999.9 KVA / 1 MVA - 9.999 MVA
- Resolution: 0.001 KVA / 0.01 KVA / 0.1 KVA / 0.001 MVA
- Accuracy: ± (1 % + 0.008 KVA) / ± (1 % + 0.08 KVA) / ± (1 % + 0.8 KVA) / ± (1 % + 0.008 MVA)
|
Reactive Power | - Measurement range: 0 KVAR - 9.999 KVAR / 10 KVAR - 99.99 KVAR / 100 KVAR - 999.9 KVAR / 1 MVAR - 9.999 MVAR
- Resolution: 0.001 KVAR / 0.01 KVAR / 0.1 KVAR / 0.001 MVAR
- Accuracy: ± (1 % + 0.008 KVAR) / ± (1 % + 0.08 KVAR) / ± (1 % + 0.8 KVAR) / ± (1 % + 0.008 MVAR)
|
Active Energy | - Measurement range: 0 KWh - 9.999 KWh / 10 KWh - 99.99 KWh / 100 KWh - 999.9 KWh / 1 MWh- 9.999 MWh
- Resolution: 0.001 KWh / 0.01 KWh / 0.1 KWh / 0.001 MWh
- Accuracy: ± (1 % + 0.008 KWh) / ± (1 % + 0.08 KWh) / ± (1 % + 0.8 KWh) / ± (1 % + 0.008 MWh)
|
Apparent Energy | - Measurement range: 0 KVAh - 9.999 KVAh / 10 KVAh - 99.99 KVAh / 100 KVAh - 999.9 KVAh / 1 MVAh- 9.999 MVAh
- Resolution: 0.001 KVAh / 0.01 KVAh / 0.1 KVAh / 0.001 MVAh
- Accuracy: ± (2 % + 0.008 KVAh) / ± (2 % + 0.08 KVAh) / ± (2 % + 0.8 KVAh) / ± (2 % + 0.008 MVAh)
|
Reactive Energy | - Measurement range: 0 KVARh - 9.999 KVARh / 10 KVARh - 99.99 KVARh / 100 KVARh - 999.9 KVARh / 1 MVARh- 9.999 MVARh
- Resolution: 0.001 KVARh / 0.01 KVARh / 0.1 KVARh / 0.001 MVARh
- Accuracy: ± (2 % + 0.008 KVARh) / ± (2 % + 0.08 KVARh) / ± (2 % + 0.8 KVARh) / ± (2 % + 0.008 MVARh)
|
Power Factor | - Measurement range: 0 - 1
- Resolution: 0.01
- Accuracy: ±0.04
|
Phase Angle | - Measurement range: -180° - 180°
- Resolution: 0.1°
- Accuracy: ±1°
|
Frequency | - Measurement range: 45 Hz - 65 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.1 Hz
|
Harmonic of AC Voltage at 50 / 60 Hz | - Measurement range: 1 - 20th order / 21 - 30th order /21 - 50th order
- Resolution: 0.001 - 1 A - 0.1 %" / 0.001 - 1 A - 0.1 % / 0.001 - 1 A - 0.1 %
- Accuracy: ± (2 % + 0.5 A) - ± (2 % + 10 Digit) / ± (2 % + 0.5 A) - ± (2 % + 10 Digit) / not specified
|
General Specifications |
Display | 3.7 in / 94.0 mm point-matrix LCD (320 240 pixel) with LED background lights |
Safety Standards | IEC1010CAT III 600V |
Input Resistance AC V | 10 MOhm |
Operating Frequency of Current Clamp | 40 Hz - 1 kHz |
Tested Operating Frequency of Current Clamp | 45 Hz - 65 Hz |
Overload Protection | - AC V: 720 V RMS
- AC A: 1300 A with current clamp
|
Data Storage | SD memory card |
Refresh Interval | 1 second |
Data Logging Function | logging with real-time speed on an SD memory card |
Record Interval | 2 - 7200 seconds |
Data Output (only for Live Display on Computer) | per USB or RS232, depending on the connection cable |
Operating Temperature | 0° C - +50° C / 32° F - 122° F |
Surrounding Humidity | - < 80 % RH
- 8 x 1.5 V AA batteries
|
Voltage Supply | 9 V adapter |
Current Drain | - Measurement Device: 300 mA DC
- Current clamp: 34 mA DC
|
Maximum Wire Diameter | 50 mm / 1.9 in |
Weight | - Measurement Device: 948 g / 33.4 oz (incl. battery)
- Current clamp: 467 g / 16.4 oz (incl. cable)
|