Voltage (AC V) | - Measurement range: 10 V - 600 V (phase to neutral) / 10 V - 600 V (phase to neutral)
- Resolution: 0.1 V / 1 pF
- Accuracy: ± (0.5 % + 0.5 V) / (4 nF - 400 µF)
|
Current (AC A) | - Measurement range: 20 A / 200 A / 1200 A
- Resolution: 0.001 A (< 10 A) - 0.01 A (≥ 10 A) / 0.01 A (< 100 A) - 0.1 A (≥ 100 A) /" 0.1 A (< 1000 A) / 1 A (≥ 1000 A)
- Accuracy: ± (0.5 % + 0.1 V) / ± (0.5 % + 0.5 A) / ± (0.5 A + 5 A)
|
Active Power | - Measurement range: 0 KW - 9.999 KW / 10 KW - 99.99 KW / 100 KW - 999.9 KW / 1 MW - 9.999 MW
- Resolution: 0.001 KW / 0.01 KW / 0.1 KW / 0.001 MW
- Accuracy: ± (1 % + 0.008 KW) / ± (1 % + 0.008 KW) / ± (1 % + 0.8 KW) / ± (1 % + 0.008 MW)
|
Apparent Power | - Measurement range: 0 KVA - 9.999 KVA / 10 KVA - 99.99 KVA / 100 KVA - 999.9 KVA / 1 MVA - 9.999 MVA
- Resolution: 0.001 KVA / 0.01 KVA / 0.1 KVA / 0.001 MVA
- Accuracy: ± (1 % + 0.008 KVA) / ± (1 % + 0.08 KVA) / ± (1 % + 0.8 KVA) / ± (1 % + 0.008 MVA)
|
Reactive Power | - Measurement range: 0 KVAR - 9.999 KVAR / 10 KVAR - 99.99 KVAR / 100 KVAR - 999.9 KVAR / 1 MVAR - 9.999 MVAR
- Resolution: 0.001 KVAR / 0.01 KVAR / 0.1 KVAR / 0.001 MVAR
- Accuracy: ± (1 % + 0.008 KVAR) / ± (1 % + 0.08 KVAR) / ± (1 % + 0.8 KVAR) / ± (1 % + 0.008 MVAR)
|
Active Energy | - Measurement range: 0 KWh - 9.999 KWh / 10 KWh - 99.99 KWh / 100 KWh - 999.9 KWh / 1 MWh- 9.999 MWh
- Resolution: 0.001 KWh / 0.01 KWh / 0.1 KWh / 0.001 MWh
- Accuracy: ± (1 % + 0.008 KWh) / ± (1 % + 0.08 KWh) / ± (1 % + 0.8 KWh) / ± (1 % + 0.008 MWh)
|
Apparent Energy | - Measurement range: 0 KVAh - 9.999 KVAh / 10 KVAh - 99.99 KVAh / 100 KVAh - 999.9 KVAh / 1 MVAh- 9.999 MVAh
- Resolution: 0.001 KVAh / 0.01 KVAh / 0.1 KVAh / 0.001 MVAh
- Accuracy: ± (2 % + 0.008 KVAh) / ± (2 % + 0.08 KVAh) / ± (2 % + 0.8 KVAh) / ± (2 % + 0.008 MVAh)
|
Reactive Energy | - Measurement range: 0 KVARh - 9.999 KVARh / 10 KVARh - 99.99 KVARh / 100 KVARh - 999.9 KVARh / 1 MVARh- 9.999 MVARh
- Resolution: 0.001 KVARh / 0.01 KVARh / 0.1 KVARh / 0.001 MVARh
- Accuracy: ± (2 % + 0.008 KVARh) / ± (2 % + 0.08 KVARh) / ± (2 % + 0.8 KVARh) / ± (2 % + 0.008 MVARh)
|
Power Factor | - Measurement range: 0 - 1
- Resolution: 0.01
- Accuracy: ±0.04
|
Phase Angle | - Measurement range: -180° - 180°
- Resolution: 0.1°
- Accuracy: ±1°
|
Frequency | - Measurement range: 45 Hz - 65 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.1 Hz
|
General Specifications |
Display | 3.7 in / 94.0 mm LCD (320 x 240 pixels) with LED backlight |
Electrical Properties | AC V, AC A, active power, apparent power, power factor, phase angle, mains frequency |
Voltage Ranges | 10 V - 600 V AC, automatic range selection |
Security / Standards | IEC1010CAT III 600V |
AC V Input Resistance | 10 MΩ |
Operation Frequency of Current Clamps | 40 Hz - 1 kHz |
Tested Operation Frequency of Current Clamps | 45 Hz - 65 Hz |
Overload Protection | AC V / 720 V rms |
AC A | 1300 A with current clips |
Memory | SD card up to 16 GB |
Measurement Display Rate | 1 second |
Data Logger | SD |
Measurement Sample Rate | 2 seconds- 7200 seconds |
Data Output | USB or RS-232, depending on the connection cable |
Operating Temperature | 0° C - 50° C / 32° F - 122° F |
Operating Humidity | < 80 % H.r. |
Power | 8 x 1.5 V AA batteries / mains component |
Input Current | - Meter: 300 mA DC
- Clamp: 34 mA DC
|
Max. Diameter | 50 mm / 1.9 in |
Weight | - Meter: 948 g / 33.4 oz (with batteries)
- Clip: 467 g / 16.4 oz (with cable)
|
Dimensions | Meter: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in |
Clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in |
Jaw: 86 mm / 3.3 in (exterior) |