Measuring Function |
AC | - Measuring range: 200 mV / 2V / 20V / 200V / 750V
- Resolution: 0.1 mV / 1 mV / 0.01V / 0.1V / 1V
- Accuracy: ± (0.8% + 5 digits) / ± (0.8% + 5 digits) / ± (0.8% + 5 digits) / ± (0.8% + 5 digits) / ± (0.8% + 5 digits)
|
Maximum Input Voltage | 750V AC |
Frequency Range | 40 - 400 Hz |
DC | - Measuring range: 200 mV / 2V / 20V / 200V / 1000V
- Resolution: 0.1 mV / 1 mV / 0.01V / 0.1V / 1V
- Accuracy: ± (0.5% + 5 digits) / ± (0.5% + 5 digits) / ± (0.5% + 5 digits) / ± (0.5% + 5 digits) / ± (0.8% + 5 digits)
|
Maximum Input Voltage | 1000V DC |
Alternating Current | - Measuring range: 200 µA / 2000 µA / 20-mA / 200-mA / 2 A / 20 A
- Resolution: 0.1 µA / 1 µA / 0.01-mA / 0.1-mA / 0.001 A / 0.01A
- Accuracy: ± (1.5% + 5 digits) / ± (1.5% + 5 digits) / ± (1.5% + 5 digits) / ± (1.5% + 5 digits) / ± (3.0% + 5 digits) / ± (3.0% + 5 digits)
|
Overload Protection at µa, Ma | 200-mA / 1000V fuse |
Overload Protection at A | 10 A / 500V fuse |
Maximum Input Current µa | 2000 µA |
Maximum Input Current Ma | 200-mA |
Maximum Input Current A | 10 A. |
Frequency Range | 40 - 400 Hz |
Direct Current | - Measuring range: 200 µA / 2000 µA / 20-mA / 200-mA / 2 A / 20 A
- Resolution: 0.1 µA / 1 µA / 0.01-mA / 0.1-mA / 0.001 A / 0.01A
- Accuracy: ± (1.2% + 5 digits) / ± (1.2% + 5 digits) / ± (1.2% + 5 digits) / ± (1.2% + 5 digits) / ± (2.0% + 5 digits) / ± (2.0% + 5 digits)
|
Overload Protection at µa, Ma | 200-mA / 1000V fuse |
Overload Protection at A | 10 A / 500V fuse |
Maximum Input Current µa | 2000 µA |
Maximum Input Current Ma | 200-mA |
Maximum Input Current A | 10 A. |
Resistance | - Measuring range: 200 Ω / 2 kΩ / 20 kΩ / 200 kΩ / 2 MΩ / 20 MΩ
- Resolution: 0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.01 MΩ
- Accuracy: ± (1.0% + 5 digits) / ± (1.0% + 5 digits) / ± (1.0% + 5 digits) / ± (1.0% + 5 digits) / ± (1.0% + 5 digits) / ± (1.0% + 5 digits)
|
Diode Measurement | - Measuring range: Indicates the forward voltage
- Resolution: 1 mV
|
Continuity Test | - Measuring range: Beep at <70 Ω
- Resolution: 0.1 Ω
|
Range Selection | Automatically and manually |
Measurement With Receiver | Detecting cable bridges, detecting cable runs |
Measurement With Network Function | Detection of open and closed circuits, wrong connection," split pair"," reverse" connection, Network integration test, screening test |
Further Measurement Function | " NCV" detection, telephone connection testing |
Display | LCD, 1999 digits |
Overload Indicator | " OIL" |
Automatic Shutdown | After 15 minutes of inactivity |
Fuses | F10A / 500V, F200mA / 1000A |
Battery Indicator | Display when the battery is discharged |
Power Supply | 9V block battery |
Operating Conditions | - 0 - 40°C / 32 - 104°F
- -10 - 50°C / 14 - 122°F
|
Dimensions | 195 x 92 x 55 mm / 7.7 x 3.6 x 2.2 in |
Weight | Approx. 400 g / < 1 lb (with batteries) |