Voltage Measurement | 4.0 - 600.0 V RMS value ± 0.5% of the measured value ± 5 digits / 0.1 V |
Voltage Peaks (> 10V) | 50 Hz - 60 Hz / ± 5% ± 50 digits |
Current Measurements | 4.0 - 1500.0 A real ± 1% V. of the measured value ± 5 digits / 0.01 A |
Current Peaks (> 20A) | 50 Hz - 60 Hz / ± 5% ± 50 digits |
Active Power P | - 10 W - 9999 kW in 5 measurement ranges
- ± 1% of the value + 20 digits (>20 V y >20 A)
- ± 2% of the value + 40 digits (>20 V y >20 A)
- 0.1 W - 1 kW according to the measurement range
|
Apparent Power S | - 10 VA - 9999 kVA in 5 measurement ranges
- ± 1% of the value + 20 digits (>20 V y >20 A)
- ± 2% of the value + 40 digits (>20 V y >20 A)
- 0.1 VA - 1 kVA according to the measurement range
|
Reactive Power Q | - 10 VAr - 9999 kVAr in 5 measurements ranges
- ± 1% of the value + 20 digits (>20 V y >20 A)
- ± 2% of the value + 40 digits (>20 V y >20 A)
- 0.1 VAr - 1 kVAr according to the measurement range
|
Pf Power Factor | - 0.000 - 1.000
- ± 0.04 (>20 V >20 A) / 0, 001
- ± 0.1 (>20 V >20 A) / 0, 001
|
Phase Angle | - -180 - +180 / ±1 / 0, 1
- 0 - +360 / ±1 / 0, 1
|
Frequency Measurement (U > 50 V) | - 46 - 65 Hz
- ±0.3 Hz / 0.1 Hz
|
Active Energy | - 0 - 999.999 kWh
- ± 1% of the value + 20 digits
|
Apparent Energy | - 0 - 999.999 kVAh
- ± 1% of the value + 20 digits
|
Reactive Energy | - 0 - 999.999 kVarh
- ± 1% of the value + 20 digits
|
Harmonics in the Voltage (Relative) 50 - 60 Hz > 80 V Ac | - 1 - 20 th / ± 2% / 0.1%
- 21 - 50 th / ± 4% of the value ± 2% / 0.1%
|
Harmonics in the Voltage (Absolute) 50 - 60 Hz > 80 V Ac | - 1 - 20 th / ± 2% / 0.1%
- 21 - 50 th / ± 4% of the value ± 0.5% / 0.1%
|
Harmonics in the Current (Relative) 50 - 60 Hz > 80 V Ac | - 1 - 20 th / ± 2% / 0.1 %
- 21 - 50 th / ± 4% of the value ± 2% / 0.1 %
|
Harmonics in the Current (Absolute) 50 - 60 Hz > 80 V Ac | - 1 - 20 th / ± 2% of the value ± 0.4 A / 0.1 A
- 21 - 50 th / ± 4% of the value ± 0.4 A / 0.1 A
|
Total Harmonic Distortion (Thd-F) 50 - 60 Hz > 80 V Y > 20 A | - 0.0 - 20% / 2% / 0.1%
- 20.1 - 100% / ± 6% of the value ± 1% / 0.1%
- 100.1 - 999.9 % / ± 10% of the value ± 1% / 0.1%
|
Max. Clamp Opening | 55 mm / 2.2 in |
Range Selection | Auto |
Overload Indication | " OL = Overload |
Memory | 50, 000 readings |
Interface | USB |
Software and Data Cable | Can be used with Win 2000, XP, ME |
Display | Graphic LCD display, 128 x 64 with backlight |
Power Supply | 2x 1.5V AA batteries |
Energy Consumption | Approx. 10-mA |
Dimensions | 271 x 112 x 46 mm / 10.6 x 4.4 x 1.8 in |
Weight | 650 g / 1.4 lbs with batteries |
Operating Conditions | 85% max. R.H. / -10 - 50°C / 14 - 122°F |
Protection / Standards | CAT III 600 V / EN 61010-2-032 |