3-Pole Earth Resistance |
Test Voltage | 20, 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Probe Resistance Rs | <100 kΩ |
Auxiliary Earth Resistance Rh | <100 kΩ |
Resolution | 0.001 Ω |
Measuring Range Re | 0.02 Ω - 300 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
4-Pole Grounding Resistor |
Test Voltage | 20, 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 30 seconds |
Probe Resistance Rs | < 100 kΩ |
Auxiliary Earth Resistance Rh | < 100 kΩ |
Resolution | 0.001 Ω |
Measuring Range Re | 0.02 Ω - 300 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
3-Pole Earth Resistance with Current Clamp |
Test Voltage | 20, 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Probe Resistance Rs | < 100 kΩ |
Auxiliary Earth Resistance Rh | < 100 kΩ |
Resolution | 0.001 Ω |
Measuring Range Re | 0.02 Ω - 20 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
4-Pole Earth Resistance with Current Clamp |
Test Voltage | 20, 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Probe Resistance Rs | < 100 kΩ |
Auxiliary Earth Resistance Rh | < 100 kΩ |
Resolution | 0.001 Ω |
Measuring Range Re | 0.02 Ω - 20 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
Grounding Resistor Only with Current Clamps |
Test Voltage | 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Measuring Range Re | 0.02 Ω - 150 Ω |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
Soil Resistance (Removal Resistance) |
Test Voltage | 20, 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Resolution | 0.001 Ω m |
Measuring Range Re | 0.02 Ω - 1000 kΩ m |
Accuracy | ± (5% + 10 digits) |
2-Pole Resistance Measurement (AC) |
Test Voltage | 20V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Measuring Range Re | 0.02 Ω - 300 kΩ |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
2-Pole Resistance Measurement (DC) |
Test Voltage | 20V DC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Measuring Range Re | 0.02 - 3 kΩ |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 3V |
Fst | 16 - 400 Hz |
4-Pole Resistance Measurement (DC) |
Test Voltage | 20V DC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Measuring Range Re | 0.02 Ω - 3 kΩ |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 3V |
Fst | 16 - 400 Hz |
Line Compensation |
Test Voltage | 20, 48V AC |
Test Frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short Circuit Current | 250-mA |
Test Time | 26 seconds |
Resolution | 0.001 Ω |
Measuring Range Re | 0.02 Ω - 30 Ω |
Accuracy | ± (3% + 10 digits) |
Ust | < 24V |
Fst | 16 - 400 Hz |
Interference Voltage |
Measuring Range | ± 50V DC |
| 1 - 50V AC |
Resolution | 0.1V |
Accuracy | ± (5% + 5 digits) |
Interference Voltage |
Measuring Range | 20-mA - 2 A |
Resolution | 1-mA |
Accuracy | ± (5% + 5 digits) |
Interference Frequency |
Measuring Range | 16 - 400 Hz |
Resolution | 1 Hz |
Accuracy | ± (1% + 10 digits) |
Other Specifications |
Data Storage | 100 readings |
Operating Conditions | 0 - 40°C / 32 - 104°F, < 80% RH (non-condensing) |
Charge Ambient Conditions To The Battery | 10 - 40°C / 50 - 104°F, < 80% rh (non-condensing) |
Storage Conditions | -10 - 50°C / 50 - 122°F, < 90% rh (non-condensing) |
Storage Conditions For The Battery | -20 - 30°C / -4 - 86°F, < 80% rh (non-condensing) |
Storage Height | < 12,000 m / 39,370 ft |
Operating Altitude | < 2,000 m / 6,561 ft |
Clamp Diameter | 51 mm |
Display | Backlit LCD, 9,999 digits |
Display Measuring Range Exceeded | > LIMIT |
Display Below Measuring Range | - |
Measuring Frequency Earthing Resistance / Leakage Current | 1 Hz (If the average value function is activated: one value every four seconds) |
Measuring Frequency Voltage Measurement | 2 Hz |
Measuring Frequency Interference Voltage | 4 Hz |
Measuring Frequency Interference Frequency | 1 Hz |
Measuring Frequency Interference Current | 1 Hz |
Interfaces | Measuring connection: E, ES, S, H, pliers connection USB-B, charging connection |
Power Supply Batteries | 6 x 1.5V D LR14 batteries |
Power Supply Battery | 1 x 7.2V nickel-metal hydride battery pack |
Power Supply Power Supply | - Primary: 100 - 240V, 50 - 60 Hz
- Secondary: 12V, 3A
|
Max. Power Consumption with Power Supply | 15V A |
Max. Power Consumption with Battery or Rechargeable Battery | 6V A |
Running Time in Battery Mode | About 5 hours |
Running Time in the Battery | About 9 hours (without backlight) |
Maximum Input Voltage |
Maximum Input Voltage Relative To Earth | 300V rms (CAT III) |
Insulation Thickness | 6880V AC: 15 seconds |
Overvoltage Protection | 250V AC between the connections |
Dimensions | 260 x 125 x 280 mm / 10.2 x 4.9 x 11 in |
Weight | About 2.5 kg / 5.5 lbs |
Standardize | - Safety: EN61010-1: 2001, EN61010-031: 2002
- Pollution degree 2, CAT III 300V,
- EMC: EN61000-3-2: 2000, IEC61326-1: 1997 A
|