Current measurement DC A |
Measuring range | Resolution/Accuracy (of rdg.) |
500 uA | 0.01 uA/+- (1% + 6 digits) |
5000 uA | 0.1 uA/+- (1% + 6 digits) |
50 A | 0.01A/+- (2.5% + 5 digits) |
1000 A | 0.1 A/+- (2.5% + 30 digits) |
Current measurement AC A |
Measuring range | Resolution/Accuracy (of rdg.) |
500 uA | 0.01 uA/+- (1.5% + 30 digits) |
5000 uA | 0.1 uA/+- (1.5% + 30 digits) |
50 A | 0.01A/+- (2.5% + 30 digits) |
1000 A | 0.1 A/+- (2.8% + 30 digits) |
Note: For AC A measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range |
Resistivity |
Measuring range | Resolution/Accuracy (of rdg.) |
500 | 0.01/+- (1% + 9 digits) |
5 k | 0.0001/+- (1% + 5 digits) |
50 k | 0.001/+- (1% + 5 digits) |
500 k | 0.01/+- (1% + 5 digits) |
5 M | 0.0001/+- (3% + 10 digits) |
50 M | 0.001/+- (3.5% + 10 digits) |
Voltage measurement DC V |
Measuring range | Resolution/Accuracy (of rdg.) |
500 mV | 0.01 mV/+- (0.1% + 8 digits) |
5V | 0.0001V/+- (0.1% + 4 digits) |
50V | 0.001 V/+- (0.1% + 4 digits) |
500V | 0.01V/+- (0.1% + 4 digits) |
600V | 0.1V/+- (0.5% + 4 digits) |
Voltage measurement AC V (50 Hz - 1000 Hz) |
Measuring range | Resolution/Accuracy (of rdg.) |
500 mV | 0.01 mV/+- (0.8% + 9 digits) (at 50 Hz / 60 Hz) |
5V | 0.0001V/+- (1% + 30 digits) |
50V | 0.001 V/+- (1% + 30 digits) |
500V | 0.01V/+- (1% + 30 digits) |
600V | 0.1V/+- (1% + 30 digits) |
Note: The accuracy specification for AC V measurements refers to the range of 5% to 100% of the measuring range |
Capacitance measurement |
Measuring range | Resolution/Accuracy (of rdg.) |
500 nF | 0.01/+- (3.5% + 40 digits) |
5000 nF | 0.1/+- (3.5% + 10 digits) |
50 uF | 0.001/+- (3.5% + 10 digits) |
500 uF | 0.01/+- (3.5% + 10 digits) |
5mF | 0.0001/+- (5% + 10 digits) |
Frequency measurement |
Measuring range | Resolution/Accuracy (of rdg.) |
50 Hz | 0.001/+- (0.3% + 2 digits) |
500 Hz | 0.01/+- (0.3% + 2 digits) |
5 kHz | 0.0001/+- (0.3% + 2 digits) |
50 khz | 0.001/+- (0.3% + 2 digits) |
500 kHz | 0.01/+- (0.3% + 2 digits) |
5 Mhz | 0.0001/+- (0.3% + 2 digits) |
10 MHz | 0.001/+- (0.3% + 2 digits) |
Duty cycle |
Measuring range | Resolution/Accuracy (of rdg.) |
5% - 95% Pulse width: 100 us - 100 ms Frequency: 10 Hz - 10 kHz | 0.1/+- (1% + 2 digits) (of the measured value) |
Temperature |
Measuring range | Resolution/Accuracy (of rdg.) |
-100°C - 1000°C / -148 - 1832°F | 0.1/+- (1% + 2.5°C / 4.5°F) |
General technical data |
Conductor diameter | Max. 48 mm |
Display | Two lines 50,000 digits |
Continuity test | 50 ohms / < 50-mA |
Diode test | 0.3-mA / 2.8V DC |
Battery indicator | Battery icon when battery low |
Overrange | OL, if measuring range exceeded |
Sample rate | 2 Hz |
Interface | Bluetooth |
Peak detection | > 1 ms |
Thermocouple | Type K |
Fuse | 500-mA ceramic quick-acting |
AC bandwidth (AC A / AC V) | 50 Hz - 400 Hz |
AC measurement | True RMS |
Operating conditions | 5°C - 40°C / 41 - 104°F, max. 80% RH at 31°C |
Storage conditions | -20°C - 60°C / -4 - 140°F, max. 80% rh |
Power supply | 9V block battery |
Automatic shutdown | After about 30 minutes |
Dimensions (W x H x D) | 230 x 76 x 40 mm / 9 x 3 x 1.6 in |
Weight | 315 g / < 1 lb |
Security | IEC 1010-1 (2001):EN 61010-1 (2001); CAT III 600V; CAT II 1000V; Degree of pollution 2 |