Ethernet Interface |
Number of Ports | 1 |
Magnetic Isolation Protection | 1.5 kV (built-in) |
10/100BaseT(X) Ports (RJ45 Connector) | Auto MDI/MDI-X connection |
Ethernet Software Features |
Configuration | Windows Utility, Telnet Console, Serial Console |
Management | ARP, BOOTP, DHCP Client, IPv4, TCP/IP, Telnet, UDP, ICMP |
Linux Real TTY Drivers | Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x |
Fixed TTY Drivers | SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X |
Android API | Android 3.1.x and later |
Windows Real COM Drivers | Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10/11 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Server 2022, Windows Embedded CE 5.0/6.0, Windows XP Embedded |
Serial Interface |
Connector | DB9 female |
Serial Standards | RS-232, RS-422, RS-485 |
Number of Ports | 1 |
Baud Rate | Supports standard Baud Rates (unit=bps): 50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230.4k |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | None, Even, Odd, Space, Mark |
Flow Control | None, RTS/CTS, XON/XOFF |
RS-485 Data Direction Control | ADDC (automatic data direction control) |
Serial Signals |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, RTS+, RTS-, CTS+, CTS-, GND |
RS-485-2w | Data+, Data-, GND |
Power Parameters |
Input Current | - 300 mA at 9 VDC
- 150 mA at 24 VDC
|
Input Voltage | 9 to 30 VDC |
Reliability |
Alert Tools | Built-in buzzer and RTC (real-time clock) |
Physical Characteristics |
Housing | Metal |
Dimensions (with ears) | 90.2 x 100.4 x 22 mm (3.55 x 3.95 x 0.87 in) |
Dimensions (without ears) | 67 x 100.4 x 22 mm (2.64 x 3.95 x 0.87 in) |
Weight | 480 g (1.06 lb) |
Environmental Limits |
Operating Temperature | 0 to 55°C (32 to 131°F) |
Storage Temperature (package included) | -40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications |
EMC | EN 55032/35 |
EMI | CISPR 32, FCC Part 15B Class B |
EMS | - IEC 61000-4-2 ESD: Contact: 4 kV
- Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
- IEC 61000-4-4 EFT: Power: 1 kV
- Signal: 0.5 kV
- IEC 61000-4-5 Surge: Power: 1 kV
- IEC 61000-4-5 Surge: Power: 1 kV
- Signal: 1 kV
- IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m
- Signal: 10 V/m
- IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m
- Signal: 3 V/m
- IEC 61000-4-11
|
Safety | UL 60950-1 |
Medical | - EN 55011: 2007+A2: 2007 Class A (Group 1) compliant
- EN 60601-1-2: 2007 compliant
|
Declaration |
Green Product | RoHS, CRoHS, WEEE |
MTBF |
Time | 225,529 hrs |
Standards | MIL-HDBK-217F |