Conditions Input impedance, Zi | 20 Hz to 20 kHz, 0 dBu, test circuit 3, RL = 600 Ω |
Typical Input impedance, Zi | 680 Ω |
Conditions Voltage gain | 1 kHz, 0 dBu, test circuit 1, Rs = 0 Ω |
Typical Voltage gain | -1.1 dB |
Conditions Magnitude response, ref 1 kHz | 20 Hz, 0 dBu, test circuit 1, Rs = 0 Ω |
Typical Magnitude response, ref 1 kHz | -0.02 dB |
Conditions Magnitude response, ref 1 kHz | 20 kHz, 0 dBu, test circuit 1, Rs = 0 Ω |
Typical Magnitude response, ref 1 kHz | +/-0.0 dB |
Conditions Deviation from linear phase (DLP) | 20 Hz to 20 kHz, 0 dBu, test circuit 1, Rs = 0 Ω |
Typical Deviation from linear phase (DLP) | +0.3 / -0 |
Conditions Distortion (THD) | 1 kHz, +4 dBu, test circuit 1, Rs = 0 Ω |
Typical Distortion (THD) | <0.001% |
Conditions Distortion (THD) | 20 Hz, +4 dBu, test circuit 1, Rs = 0 Ω |
Typical Distortion (THD) | 0.004% |
Conditions Maximum output level | 20 Hz, 1% THD, test circuit 1, Rs = 0 Ω |
Typical Maximum output level | +22 dBu |
Conditions Output impedance, Zo | 20 Hz to 20 kHz, 0dBu, test circuit 4 |
Typical Output impedance, Zo | 80 Ω |