Conditions Input impedance, Zi | 1 kHz, +4 dBu, test circuit 1 |
Typical Input impedance, Zi | 23.5 kΩ |
Conditions Insertion loss | 1 kHz, +4 dBu, test circuit 1 |
Typical Insertion loss | 1.6 dB |
Conditions Magnitude response, ref 1 kHz | 20 Hz, +4 dBu, test circuit 1 |
Typical Magnitude response, ref 1 kHz | -0.03 dB |
Conditions Magnitude response, ref 1 kHz | 20 kHz, +4 dBu, test circuit 1 |
Typical Magnitude response, ref 1 kHz | -0.70 dB |
Conditions Deviation from linear phase (DLP) | 20 Hz to 20 kHz, +4 dBu, test circuit 1 |
Typical Deviation from linear phase (DLP) | +1.4/-0 |
Conditions Distortion (THD) | 1 kHz, +4 dBu, test circuit 1 |
Typical Distortion (THD) | <0.001% |
Conditions Distortion (THD) | 20 Hz, +4 dBu, test circuit 1 |
Typical Distortion (THD) | 0.04% |
Conditions Maximum 20 Hz input level | 1% THD, test circuit 1 |
Typical Maximum 20 Hz input level | +19 dBu |
Conditions Output impedance, Zo | 1 kHz, test circuit 1 |
Typical Output impedance, Zo | 4.65 kΩ |