Product Characteristics |
Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
Communication Interface | IO-Link |
Process Connection | Clamp DN25 - DN40 (1 - 1,5") DIN 32676 (ISO 2852) |
Installation length EL [mm] | 100 |
System | Gold-plated contacts |
Measuring Element | 1 x Pt 1000 |
Reference element | 1 x NTC |
Media | Liquids and gases |
Pressure Rating [bar] | 160 |
Electrical Data |
Operating Voltage [V] | 18 - 32 DC; (cULus - Class 2 source required) |
Current Consumption [mA] | 10; (24 V) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 6 |
Integrated Watchdog | Yes |
Inputs / Outputs |
Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
Outputs |
Total Number of Outputs | 2 |
Output Signal | Analog signal; IO-Link; calibration check status |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 1 |
Output Function | Normally closed; (diagnostic signal) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 100 |
Diagnostic output | Calibration check status and error diagnostics |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20 |
Maximum Load [Ω ] | (Ub - 15 V) x 50 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Note on measuring range |
Factory Setting | -10 - 150 ° C / 14 - 302 ° F |
Calibration check limit [K] | 0.5 - 3 |
In steps of [K] | 0.05 |
Resolution |
Resolution of Analog Output [K] | 0.05 |
Accuracy / Deviations |
Precision analog output [K] | ± 0,2 |
Precision IO-Link [K] | ± 0,2 |
Temperature coefficient analog output [% of the span / 10 K] | < ± 0,02; (In case of deviation from the reference condition 25 ± 5 ° C) |
Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (In case of deviation from the reference condition 25 ± 5 ° C) |
Reaction Times |
Dynamic Response T05 / T09 [s] | 1,5 / 4 |
Software / Programming |
Parameter Setting | Display Unit; scaling of the analog output; calibration check limit; switching logic diagnostic output; simulation mode |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 CDV |
Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 1 |
Process Data Binary | 1 |
Minimum Process Cycle Time [ms] | 4.4 |
IO-Link Resolution Temperature [K] | 0.01 |
Operating Conditions |
Ambient Temperature [° C] | -25 - 70 |
Storage Temperature [° C] | -40 - 100 |
Protection | IP 68; IP 69K |
MTTF [Years] | 329 |
Mechanical Data |
Weight [g] | 358.9 |
Dimensions [mm] | Ø 50 / L = 164.8 |
Material | Stainless steel (1.4404 / 316L); PEI; FKM; PFA |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); PEEK |
Process Connection | Clamp DN25 - DN40 (1 - 1,5") DIN 32676 (ISO 2852) |
Surface characteristics Ra/Rz of the wetted parts | Ra: <0.8 |
Probe Diameter [mm] | 6 |
Installation length EL [mm] | 100 |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |