Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Process Connection | Threaded connection G 1/2 DN8 |
System | Gold-plated contacts |
Media | Water; glycol solutions; Coolants |
Medium Temperature [° C] | -10 - 90 |
Pressure Rating [bar] | 12 |
Pressure Rating [MPa] | 1.2 |
|
MAWP (for Applications According to CRN) [bar] | 3.9 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC |
Current Consumption [mA] | < 30 |
Minimum Insulation Resistance [MΩ ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | < 3 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; frequency signal; IO-Link; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 100 |
Short-Circuit Protection | Yes |
Overload Protection | Yes |
Measuring/Setting Range |
Frequency at the end point FRP [Hz] | 100 - 1000 |
Measuring dynamics | 1: 20 |
Temperature Monitoring |
Measuring Range [° C] | -10 - 90 |
Display range [° C] | -30 - 110 |
Resolution [° C] | 0.5 |
Set point SP [° C] | -9 - 90 |
Reset point rP [° C] | -10 - 89 |
In Steps of [° C] | 0.5 |
Frequency start point, FSP [° C] | -10 - 70 |
Frequency end point, FEP [° C] | 10 - 90 |
Frequency at the end point FRP [Hz] | 100 - 1000 |
Accuracy / deviations Flow monitoring |
Accuracy (in the Measuring Range) | ± 2 % MEW; (water) |
Repeatability | ± 0,5 % MEW |
Temperature Monitoring |
Accuracy [K] | ± 1 |
Reaction Times Flow monitoring |
Response Time [s] | 1; (dAP = 0) |
Damping Process Value dAP [s] | 0 - 5 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 6 |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display Unit |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 2 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 3 |
Operating Conditions |
Ambient Temperature [° C] | 0 - 60 |
Storage Temperature [° C] | -20 - 80 |
Protection | |
MTTF [Years] | 342 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 474 |
Material | Stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
Tightening Torque [Nm] | 30 |
Process Connection | Threaded connection G 1/2 DN8 |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |