Product CharacteristicsNumber of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Threaded connection G 1 flat seal |
System | Gold-plated contacts |
Application | Totalizer function; for industrial applications |
Installation | Connection to pipe by means of an adapter |
Media | Water; glycol solutions; Coolants; oils |
Medium temperature [° F] | 14 - 176 |
Pressure Rating [bar] | 16 |
Pressure rating [psi] | 232 |
Electrical Data |
Operating Voltage [V] | 19 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | 100 |
Minimum Insulation Resistance [MΩ ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 10 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Inputs |
Inputs | Counter reset |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; analog signal; pulse signal; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 250; (per output) |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 500 |
Analog Voltage Output [V] | 0 - 10; (scalable) |
Minimum Load Resistance [Ω ] | 2000 |
Pulse output | Flow rate meter |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Volumetric flow quantity monitoring |
Pulse value | 0.02 - 9000 * 10³ gal |
In steps of | 0.02 gal |
Pulse length [s] | 0,3 - 2 |
Temperature Monitoring |
Measuring range [° F] | 14 - 176 |
Resolution [° F] | 0.5 |
Set point SP [° F] | 14.5 - 176 |
Reset point rP [° F] | 14 - 175.5 |
Analog start point [° F] | 14 - 145.5 |
Analog end point [° F] | 44.5 - 176 |
In steps of [° F] | 0.5 |
Accuracy / deviations Flow monitoring |
Accuracy (in the Measuring Range) | Water: <± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm² /s at 40 ° C): <± (5 % MW + 0,5 % MEW) |
Repeatability | 0,05 gpm; 3 gph |
Temperature Monitoring |
Accuracy [K] | ± 5,4 (Q>0,26 gpm) |
Reaction Times Flow monitoring |
Response Time [s] | 0.25; (dAP = 0) |
Delay Time Programmable dS, dr [s] | 0 - 50 |
Damping Process Value dAP [s] | 0 - 1 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 70 (Q>1 gpm); (water) |
Software / Programming |
Parameter Setting | Flow monitoring; quantity meter; Preset counter; Temperature Monitoring |
Operating Conditions |
Ambient Temperature [° F] | 14 - 140 |
Storage Temperature [° F] | -13 - 176 |
Protection | IP 67 |
MTTF [Years] | 185 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 1666.5 |
Material | Housing: AlMgSi0.5 anodized; sealing: FKM; PA 6.6; cover film: PA |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process Connection | Threaded connection G 1 flat seal |