Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Process Connection | Threaded connection G 3/4 flat seal |
System | Gold-plated contacts |
Installation | Connection to pipe by means of an adapter |
Media | Water; glycol solutions; Coolants; oils |
Medium Temperature [° C] | -10 - 80 |
Electrical Data |
Operating Voltage [V] | 19 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | 100 |
Minimum Insulation Resistance [MΩ ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 10 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal |
Electrical Design | PNP |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 250; (per output) |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Maximum flow rate [l/min] | 60 |
Temperature Monitoring |
Measuring Range [° C] | -10 - 80 |
Resolution [° C] | 0.2 |
Set point SP [° C] | -9.8 - 80 |
Reset point rP [° C] | -10 - 79.8 |
In Steps of [° C] | 0.2 |
Accuracy / deviations Flow monitoring |
Accuracy (in the Measuring Range) | Water: <± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm² /s at 40 ° C): <± (5 % MW + 0,5 % MEW) |
Repeatability | 0,1 l/min (0,025 gpm) |
Temperature Monitoring |
Accuracy [K] | 0,2 |
Reaction Times Flow monitoring |
Response Time [s] | 0.25; (dAP = 0) |
Delay Time Programmable dS, dr [s] | 0 - 50 |
Damping Process Value dAP [s] | 0 - 1 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 70 (Q>5 l/min); (water) |
Software / Programming |
Parameter Setting | Flow monitoring; Temperature Monitoring |
Operating Conditions |
Ambient Temperature [° C] | -10 - 60 |
Storage Temperature [° C] | -25 - 80 |
Protection | IP 67 |
MTTF [Years] | 246 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 1535.5 |
Material | Housing: AlMgSi0.5 anodized; sealing: FKM; PA 6.6; cover film: PA |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process Connection | Threaded connection G 3/4 flat seal |
Display Unit | L/min; m³/h; gpm; gph; ° C; ° F |