Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Threaded connection G 3/4 DN20 flat seal |
System | Gold-plated contacts |
Application | Totalizer function; for industrial applications |
Installation | Connection to pipe by means of an adapter |
Media | Conductive liquids; water; water-based media |
Medium temperature [° F] | 14 - 158 |
Pressure Rating [bar] | 16 |
Pressure rating [psi] | 232 |
MAWP (for Applications According to CRN) [bar] | 11.2 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | 95; (24 V) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 5 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Inputs |
Inputs | Counter reset |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 200 |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 500 |
Analog Voltage Output [V] | 0 - 10; (scalable) |
Minimum Load Resistance [Ω ] | 2000 |
Pulse output | Flow rate meter |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Volumetric flow quantity monitoring |
Pulse value | 0.01 - 99 990 000 gal |
Pulse length [s] | 0,005 - 2 |
Temperature Monitoring |
Measuring range [° F] | -4 - 176 |
Resolution [° F] | 0.5 |
Set point SP [° F] | -2.5 - 176 |
Reset point rP [° F] | -3.5 - 175 |
Analog start point [° F] | -4 - 140.5 |
Analog end point [° F] | 31.5 - 176 |
In steps of [° F] | 0.5 |
Accuracy / deviations Flow monitoring |
Accuracy (in the Measuring Range) | ± (0,8 % MW + 0,5 % MEW) |
Repeatability | ± 0,2% MEW |
Temperature Monitoring |
Accuracy [K] | ± 2,5 (Q>0,26 gpm) |
Reaction Times Flow monitoring |
Response Time [s] | 0.15; (dAP = 0, T19) |
Delay Time Programmable dS, dr [s] | 0 - 50 |
Damping Process Value dAP [s] | 0 - 5 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 20 (Q>0,26 gpm) |
Software / Programming |
Parameter Setting | Flow monitoring; quantity meter; Preset counter; Temperature Monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display Unit |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 3 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 5 |
Operating Conditions |
Ambient Temperature [° F] | 14 - 140 |
Storage Temperature [° F] | -13 - 176 |
Protection | IP 67 |
MTTF [Years] | 145 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 586 |
Material | Stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); PEEK; FKM |
Process Connection | Threaded connection G 3/4 DN20 flat seal |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |