Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Process Connection | M18 x 1,5 Internal thread |
Media | Liquids; Gases |
Medium Temperature [° C] | -25 - 80 |
Pressure Rating [bar] | 300 |
Liquids |
Medium Temperature [° C] | -25 - 80 |
Gases |
Medium Temperature [° C] | -25 - 80 |
Electrical Data |
Operating Voltage [V] | 18 - 36 DC |
Current Consumption [mA] | < 60 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 10 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; IO-Link; (configurable) |
Electrical Design | PNP |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 250 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Probe Length L [mm] | 45 |
Liquids |
Setting Range [cm/s] | 3 - 300 |
Greatest sensitivity [cm/s] | 3 - 100 |
Gases |
Setting Range [cm/s] | 200 - 3000 |
Greatest sensitivity [cm/s] | 200 - 800 |
Temperature Monitoring |
Measuring Range [° C] | 2 - 80 |
Resolution [° C] | 1 |
Accuracy / Deviations |
Repeatability [cm/s] | 1 - 5 |
Temperature Drift [cm/s x 1/K] | 0.1; (for water 5 - 100 cm/s; 10 - 70 ° C) |
Maximum Temperature Gradient of Medium [K/min] | 300 |
Switch point accuracy [cm/s] | ± 2 - ± 10; (for water 5 - 100 cm/s; 25 ° C; Factory Setting) |
Hysteresis [cm/s] | 2 - 5; (for water 5 - 100 cm/s; 25 ° C; Factory Setting) |
Temperature Monitoring |
Switch point accuracy [K] | ± 3 (v>5cm/s); (Liquids) |
Resolution [K] | 1 |
Hysteresis [K] | 2 |
Repeatability [K] | 2 |
Reaction Times |
Response Time [s] | 1 - 10 |
Liquids |
Response Time [s] | 1 - 10 |
Gases |
Response Time [s] | 1 - 10 |
Temperature Monitoring |
Response Time [s] | 1 - 10 |
Software / Programming |
Adjustment of the switch point | Pushbuttons |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 2 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 3 |
Operating Conditions |
Ambient Temperature [° C] | -25 - 80 |
Storage Temperature [° C] | -25 - 100 |
Protection | |
MTTF [Years] | 277 |
Mechanical Data |
Weight [g] | 231.5 |
Dimensions [mm] | M18 x 1.5 |
Thread Designation | M18 x 1.5 |
Material | Stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
Process Connection | M18 x 1,5 Internal thread |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |