Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Flange DN65 DIN 2448 according to: DIN EN 10220 |
Media | Compressed air |
Medium Temperature [° C] | -10 - 60 |
Min. bursting pressure [bar] | 64 |
Min. bursting pressure [MPa] | 6.4 |
Pressure Rating [bar] | 16 |
Pressure Rating [MPa] | 1.6 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | < 80 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 1 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Inputs |
Inputs | Counter reset |
Outputs |
Output Signal | Switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 150; (per output) |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 500 |
Pulse output | Consumed quantity meter |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Pressure monitoring |
Measuring range [bar] | -1 - 16 |
Display range [bar] | -1 - 20 |
Resolution [bar] | 0.05 |
Set point SP [bar] | -0.92 - 16 |
Reset point rP [bar] | -1 - 15.92 |
Analog start point [bar] | -1 - 12.8 |
Analog end point [bar] | 2.2 - 16 |
In steps of [bar] | 0.01 |
Volumetric flow quantity monitoring |
Pulse length [s] | 0.002 - 2 |
Accuracy / Deviations |
Accuracy (in the Measuring Range) | Class 141: ± (3 % MW + 0,3 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1: 2010; reference conditions: inlet pipe length>= 113 cm outlet pipe length>= 15 cm; reference temperature: 18..26 ° C; standard volume flow 8 - 1155 m³/h; (standard volume flow DIN_ISO_2533 15 ° C, 1013,25 mbar, 0 % r.H.) |
Pressure monitoring |
Repeatability [% of the final value] | ± 0,2 |
Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,3 |
Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,1 |
Temperature Monitoring |
Accuracy [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
Reaction Times |
Response Time [s] | 0.1; (dAP = 0) |
Damping Process Value dAP [s] | 0 - 5 |
Pressure monitoring |
Response Time [s] | 0.05 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 0,5 |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 CDV |
Profiles | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 8 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 7.2 |
Operating Conditions |
Ambient Temperature [° C] | 0 - 60 |
Storage Temperature [° C] | -20 - 85 |
Maximum Relative Air Humidity [%] | 90 |
Protection | |
MTTF [Years] | 167 |
Pressure Equipment Directive | Modul A; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 9630 |
Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM |
Materials (Wetted Parts) | Stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; Pipe section: stainless steel (1.4301 / 304) |
Process Connection | Flange DN65 DIN 2448 according to: DIN EN 10220 |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |