Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Threaded connection G 1/4 DN8 |
Media | Compressed air |
Medium Temperature [° C] | 0 - 60 |
Pressure Rating [bar] | 16 |
Pressure Rating [MPa] | 1.6 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | < 110 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 1 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical Design | PNP |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 250; (per output) |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 500 |
Pulse output | Consumed quantity meter |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Volumetric flow quantity monitoring |
Pulse value | 0.001 - 1000000 m³ |
In steps of | 0.001 m³ |
Pulse length [s] | 0,1 - 2 |
Temperature Monitoring |
Measuring Range [° C] | 0 - 60 |
Display range [° C] | -12 - 72 |
Accuracy / deviations Flow monitoring |
Repeatability [% of the measured value] | ± 1,5 |
Accuracy (in the Measuring Range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN8) |
Temperature Monitoring |
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
Reaction Times Flow monitoring |
Response Time [s] | 0.1; (dAP = 0) |
Damping Process Xalue dAP in Steps [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Software / Programming |
Parameter Setting | Flow monitoring; quantity meter; Preset counter; Temperature Monitoring; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 CDV |
Profiles | No profile |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 3 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 4.1 |
Operating Conditions |
Ambient Temperature [° C] | 0 - 60 |
Storage Temperature [° C] | -20 - 85 |
Maximum Relative Air Humidity [%] | 90 |
Protection | IP 65 |
MTTF [Years] | 227 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 974 |
Material | PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated |
Materials (Wetted Parts) | Stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polYester; aluminum |
Process Connection | Threaded connection G 1/4 DN8 |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |