Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Measuring range [scfh] | 80 - 24720 |
Measuring range [scfm] | 1.5 - 412 |
Measuring range [ft/s] | 1 - 275.6 |
Process Connection | Threaded connection 2" NPT DN50 |
Media | Compressed air |
Medium Temperature [° C] | -10 - 60 |
Min. bursting pressure [psi] | 928 |
Pressure rating [psi] | 232 |
MAWP (for Applications According to CRN) [bar] | 9.5 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | < 80 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 1 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Inputs |
Inputs | Counter reset |
Outputs |
Output Signal | Switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 150; (per output) |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 500 |
Pulse output | Consumed quantity meter |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Measuring range [scfh] | 80 - 24720 |
Measuring range [scfm] | 1.5 - 412 |
Measuring range [ft/s] | 1 - 275.6 |
Display range [scfh] | 0 - 29660 |
Display range [scfm] | 0 - 494.5 |
Display range [ft/s] | 0 - 330.8 |
Resolution [scfh] | 20 |
Resolution [scfm] | 0.5 |
Resolution [ft/s] | 0.2 |
Set point SP [scfh] | 210 - 24710 |
Set point SP [scfm] | 3.5 - 411.8 |
Set point SP [ft/s] | 2.4 - 275.5 |
Reset point rP [scfh] | 90 - 24590 |
Reset point rP [scfm] | 1.5 - 409.8 |
Reset point rP [ft/s] | 1 - 274.1 |
Analog start point ASP [scfh] | 0 - 19780 |
Analog start point ASP [scfm] | 0 - 329.6 |
Analog start point ASP [ft/s] | 0 - 220.5 |
Analog end point AEP [scfh] | 4940 - 24720 |
Analog end point AEP [scfm] | 82.4 - 412 |
Analog end point AEP [ft/s] | 55.1 - 275.6 |
Low flow cut-off LFC [scfh] | 70 - 250 |
Low flow cut-off LFC [scfm] | 1.2 - 4.1 |
Low flow cut-off LFC [ft/s] | 0.8 - 2.8 |
In steps of [scfh] | 1 |
In steps of [scfm] | 0.1 |
In steps of [ft/s] | 0.1 |
Pressure monitoring |
Measuring range [psi] | -15 - 232 |
Display range [psi] | -15 - 290 |
Resolution [psi] | 1 |
Set point SP [psi] | -13 - 232 |
Reset point rP [psi] | -15 - 231 |
Analog start point [psi] | -15 - 186 |
Analog end point [psi] | 32 - 232 |
In steps of [psi] | 1 |
Volumetric flow quantity monitoring |
Pulse length [s] | 0.002 - 2 |
Accuracy / Deviations |
Temperature Coefficient [1/K] | ± 0,07 % MW |
Accuracy (in the Measuring Range) | Class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1: 2010; at medium temperature 73 ° F |
Repeatability | ± (0,4 % MW + 0,1 % MEW) |
Pressure monitoring |
Repeatability [% of the final value] | ± 0,2 |
Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,3 |
Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,1 |
Temperature Monitoring |
Accuracy [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
Reaction Times |
Response Time [s] | 0.1; (dAP = 0) |
Damping Process Value dAP [s] | 0 - 5 |
Pressure monitoring |
Response Time [s] | 0.05 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 0,5 |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 CDV |
Profiles | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 8 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 7.2 |
Operating Conditions |
Ambient Temperature [° F] | 32 - 140 |
Storage Temperature [° F] | -4 - 185 |
Maximum Relative Air Humidity [%] | 90 |
Protection | |
MTTF [Years] | 183 |
Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical Data |
Weight [g] | 2681.5 |
Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
Materials (Wetted Parts) | Stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
Process Connection | Threaded connection 2" NPT DN50 |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |