Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Threaded connection G 3/4 |
System | Gold-plated contacts |
Media | Liquids; water; glycol solutions; Coolants |
Medium Temperature [° C] | -10 - 100 |
Pressure Rating [bar] | 25 |
Pressure Rating [MPa] | 2.5 |
MAWP (for Applications According to CRN) [bar] | 25 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | < 50 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | < 3 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; analog signal; frequency signal; IO-Link; (configurable) |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 150; (per output 2 x 200 ( - 60 ° C); 2 x 250 ( - 40 ° C)) |
Switching cycles (mechanical) | 10 million |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20 |
Maximum Load [Ω ] | 500 |
Short-Circuit Protection | Yes |
Overload Protection | Yes |
Frequency of the output [Hz] | 0 - 10000 |
Measuring/Setting Range |
Frequency at the end point FRP [Hz] | 10 - 10000 |
Measuring dynamics | 1: 50 |
Temperature Monitoring |
Measuring Range [° C] | -10 - 100 |
Display range [° C] | -32 - 122 |
Resolution [° C] | 1 |
Set point SP [° C] | -9 - 100 |
Reset point rP [° C] | -10 - 99 |
In Steps of [° C] | 1 |
Frequency start point, FSP [° C] | -10 - 78 |
Frequency end point, FEP [° C] | 12 - 100 |
Frequency at the end point FRP [Hz] | 10 - 10000 |
Accuracy / deviations Flow monitoring |
Accuracy (in the Measuring Range) | ± (4 % MW + 1 % MEW); (Q>2 l/min; medium and operating temperature: +22 ° C ± 4K) |
Repeatability | ± 1 % MEW |
Temperature Monitoring |
Temperature Drift | 0,029 ° C / K |
Accuracy [K] | 3 K (25° C; Q>1 l/min) |
Reaction Times Flow monitoring |
Response Time [s] | 0.01 |
Damping Process Value dAP [s] | 0 - 5 |
Damping for the Analog Output dAA [s] | 0 - 5 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | T09 = 120 (Q>1 l/min) |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 CDV |
Profiles | Smart Sensor: Process Data Variable; Device Identification |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 2 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 5 |
Operating Conditions |
Ambient Temperature [° C] | 0 - 60 |
Storage Temperature [° C] | -15 - 80 |
Protection | |
MTTF [Years] | 145 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 1488.75 |
Material | Stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
Materials (Wetted Parts) | Stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
Process Connection | Threaded connection G 3/4 |
Notes | Please note the changed housing design! |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |