Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Diameter Ø 8 mm |
System | Gold-plated contacts |
Installation | Recommended for pipe diameters; ( 15 - 400 mm) |
Media | Air |
Medium Temperature [° C] | -20 - 100 |
Pressure Rating [bar] | 50 |
Pressure Rating [MPa] | 5 |
MAWP (for Applications According to CRN) [bar] | 50 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | < 100 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 10 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; analog signal; frequency signal; IO-Link; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 250 |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 350 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Frequency of the output [Hz] | 0 - 1000 |
Measuring/Setting Range |
Probe Length L [mm] | 200 |
Operating Mode | Relative; absolutely gaseous; (absolute: reference measurement recommended; Factory Setting: relative) |
Display range [m/s] | 0 - 36 |
Resolution [m/s] | 0.2 |
Set point SP [m/s] | 2 - 30 |
Reset point rP [m/s] | 0.6 - 28.6 |
Analog start point ASP [m/s] | 0 - 24 |
Analog end point AEP [m/s] | 6 - 30 |
Frequency end point, FEP [m/s] | 6.6 - 30 |
Frequency at the end point FRP [Hz] | 100 - 1000 |
Gases - Operating Mode " absolute" |
Setting Range [m/s] | 0 - 30 |
Greatest Sensitivity [m/s] | 0.6 - 30 |
Gases - Operating Mode " relative" |
Setting Range [m/s] | 0 - 60 |
Greatest Sensitivity [m/s] | 0.6 - 30 |
Temperature Monitoring |
Measuring Range [° C] | -20 - 100 |
Resolution [° C] | 0.2 |
Accuracy / deviations Gases - Operating Mode " absolute" |
Repeatability | ± (3 % MW + 0,6 % MEW) |
Gases - Operating Mode " relative" |
Accuracy | ± (10 % MW + 2 % MEW); (reference conditions: DN50; Inside diameter 51 mm; within the range of maximum sensitivity: 20 ° C /<6 bar; Insertion depth: 15 mm; inlet pipe length: 2.5 m; standard velocity to DIN ISO 2533 at the sensor tip) |
Repeatability | ± (3 % MW + 0,6 % MEW) |
Temperature Monitoring |
Temperature Drift | ± 0,005 K/° C |
Accuracy [K] | ± 2 / + 8; (flow velocity>20 % VMR and 20 ° C: ± 2) |
Reaction Times |
Response Time [s] | 7 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | 30 (T09); (Flow velocity: ≥ 10 m/s) |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 2 |
Process Data Binary | 2 |
Minimum Process Cycle Time [ms] | 3 |
Operating Conditions |
Ambient Temperature [° C] | -40 - 80 |
Storage Temperature [° C] | -40 - 100 |
Protection | |
MTTF [Years] | 131 |
Mechanical Data |
Weight [g] | 343.8 |
Material | Stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30 |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L) |
Process Connection | Diameter Ø 8 mm |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |