Product Characteristics |
Number of Inputs and Outputs | Number of Analog Outputs: 2 |
Process Connection | Diameter Ø 8 mm |
System | Gold-plated contacts |
Media | Water; glycol solutions; air; oils |
Medium temperature [° F] | -4 - 212 |
Pressure Rating [bar] | 50 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC |
Current Consumption [mA] | < 100 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 10 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Analog Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Analog signal |
Number of Analog Outputs | 2 |
Analog Current Output [mA] | 4 - 20; (scalable) |
Maximum Load [Ω ] | 350 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Probe Length L [mm] | 100 |
Operating Mode | Relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory Setting: relative) |
Liquids |
Resolution [ft/s] | 0.05 |
Analog start point ASP [ft/s] | 0 - 7.95 |
Analog end point AEP [ft/s] | 1.9 - 9.85 |
Gases |
Resolution [ft/s] | 2 |
Analog start point ASP [ft/s] | 0 - 264 |
Analog end point AEP [ft/s] | 64 - 328 |
Temperature Monitoring |
Measuring range [° F] | -4 - 212 |
Resolution [° F] | 0.5 |
Analog start point [° F] | -4 - 169 |
Analog end point [° F] | 39 - 212 |
In steps of [° F] | 0.5 |
Liquid Media - Absolute Operating Mode |
Setting Range [ft/s] | 0 - 9.85 |
Greatest sensitivity [ft/s] | 0.15 - 9.85 |
Liquid media - Relative Operating Mode |
Setting Range [ft/s] | 0 - 19.5 |
Greatest sensitivity [ft/s] | 0.15 - 9.85 |
Gases - Operating Mode " absolute" |
Setting Range [ft/s] | 0 - 328 |
Greatest sensitivity [ft/s] | 6 - 328 |
Gases - Operating Mode " relative" |
Setting Range [ft/s] | 0 - 656 |
Greatest sensitivity [ft/s] | 6 - 328 |
Accuracy / Deviations |
Temperature Drift [cm/s x 1/K] | 0,01 fps x 1/K (<68 ° F; >158 ° F) |
Maximum Temperature Gradient of Medium [K/min] | 100 |
Absolute Operating Mode |
Repeatability | 0,05 m/s; (water; Flow velocity: 0,05 - 3 m/s) |
Relative Operating Mode |
Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions: ; water: 68 - 158 ° F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
Repeatability | 0,05 m/s; (water; Flow velocity: 0,05 - 3 m/s) |
Temperature Monitoring |
Temperature Drift | ± 0,003 K/° F |
Accuracy [K] | ± 0,3 / ± 1; (water; Flow velocity: 1 - 9,85 fps / air; Flow velocity: >32,8 fps) |
Reaction Times |
Response Time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | 1,5 (T09); (water; Flow velocity: 1 - 9,85 fps) |
Software / Programming |
Parameter Setting | Medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color |
Operating Conditions |
Ambient Temperature [° F] | -40 - 176 |
Storage Temperature [° F] | -40 - 212 |
Protection | |
MTTF [Years] | 179 |
Mechanical Data |
Weight [g] | 262 |
Material | Stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30 |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L) |
Process Connection | Diameter Ø 8 mm |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |