Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Process Connection | Threaded connection G 1/4 external thread Internal thread: M5 |
Media | Liquids and gases |
Conditionally Suitable for | Use in gases at pressures>25 bar only on request |
Medium Temperature [° C] | -25 - 90 |
Type of Pressure | Relative pressure |
Electrical Data |
Operating Voltage [V] | 9.6 - 36 DC; (communication mode: 18 - 32) |
Current Consumption [mA] | < 45 |
Minimum Insulation Resistance [MΩ ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | 0.3 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal |
Electrical Design | NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 250 |
Switching Frequency DC [Hz] | 170 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Accuracy / Deviations |
Switch Point Accuracy [% of the Span] | < ± 0,5 |
Repeatability [% of the Span] | < ± 0,1; (with temperature fluctuations<10 K) |
Characteristics Deviation [% of the Span] | < ± 0,25 (BFSL) /<± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis Deviation [% of the Span] | < ± 0,1 |
Long-Term Stability [% of the Span] | < ± 0,1; (per year) |
Temperature coefficient Zero Point [% of the Span / 10 K] | < ± 0,2; (0 - 80 ° C) |
Temperature Coefficient Span [% of the Span / 10 K] | < ± 0,2; (0 - 80 ° C) |
Reaction Times |
Response Time [ms] | < 3 |
Damping Process Xalue dAP in Steps [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
Operating Conditions |
Ambient Temperature [° C] | -25 - 85 |
Storage Temperature [° C] | -40 - 100 |
Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
MTTF [Years] | 309 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 226 |
Material | Stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
Materials (Wetted Parts) | Stainless steel (1.4305 / 303); ceramics; FKM |
Minimum Pressure Cycles | 100 million |
Process Connection | Threaded connection G 1/4 external thread Internal thread: M5 |
Restrictor Element Integrated | No (can be retrofitted) |
Teach function | Yes |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |