Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Process Connection | Threaded connection G 1/8 Internal thread |
System | gold-plated contacts |
Media | Compressed air |
Conditionally Suitable for | Other media on request |
Medium Temperature [°C] | 0 - 60 |
Type of Pressure | Relative pressure; vacuum |
Electrical Data |
Operating Voltage [V] | 18 - 36 DC; (to SELV/PELV) |
Current Consumption [mA] | <50 |
Minimum Insulation Resistance [MΩ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Overvoltage protection | Yes; (<40 V) |
Power-on Delay Time [s] | 0.3 |
Integrated Watchdog | Yes |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 250 |
Switching Frequency DC [Hz] | <170 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Accuracy / Deviations |
Switch Point Accuracy [% of the Span] | ± 0,5 |
Repeatability [% of the Span] | ± 0,1; (with temperature fluctuations<10 K) |
Characteristics Deviation [% of the Span] | ± 0,25 (BFSL) /<± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis Deviation [% of the Span] | ± 0,25 |
Long-Term Stability [% of the Span] | ± 0,05; (per 6 months) |
Temperature coefficient Zero Point [% of the Span / 10 K] | 0,2; (0 - 60 °C) |
Temperature Coefficient Span [% of the Span / 10 K] | 0,2; (0 - 60 °C) |
Reaction Times |
Delay Time Programmable dS, dr [s] | 0; 0,2 - 50 |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; Diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display Unit |
Operating Conditions |
Ambient Temperature [°C] | -25 - 85 |
Storage Temperature [°C] | -25 - 85 |
Protection | IP 67 |
MTTF [Years] | 284 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 173.5 |
Material | Stainless steel (1.4301 / 304); PPS; PC; PBT; PEI; FKM |
Materials (Wetted Parts) | Stainless steel (1.4567 / 304Cu); brass; FKM; PPS; silicon (coated) |
Minimum Pressure Cycles | 50 million |
Process Connection | Threaded connection G 1/8 Internal thread |