Product Characteristics |
Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
Process Connection | Threaded connection G 1/2 external thread sealing cone |
System | gold-plated contacts |
Measuring Element | Ceramic-capacitive pressure measuring cell |
Temperature Monitoring | Yes |
Media | viscous media and liquids with suspended particles; liquids and gases |
Conditionally Suitable for | Use in gases at pressures>25 bar only on request |
Medium Temperature [°C] | -25 - 150 |
Vacuum Resistance [mbar] | -1000 |
Type of Pressure | Relative pressure; vacuum |
No Dead Space | Yes |
MAWP (for Applications According to CRN) [bar] | 43 |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC |
Minimum Insulation Resistance [MΩ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Integrated Watchdog | Yes |
3-Wire |
Current Consumption [mA] | 3.5 - 21.5 |
Power-on Delay Time [s] | <1 |
3-Wire |
Current Consumption [mA] | <45 |
Power-on Delay Time [s] | <0.5 |
Inputs / Outputs |
Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
Outputs |
Total Number of Outputs | 2 |
Output Signal | Analog signal; IO-Link; (configurable) |
Number of Digital Outputs | 1; (IO-Link) |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (scalable; 1: 5) |
Maximum Load [Ω] | 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) |
Short-circuit proof | Yes |
Overload Protection | Yes |
Accuracy / Deviations |
Repeatability [% of the Span] | ± 0,1; (with temperature fluctuations<10 K; Turn down 1: 1) |
Characteristics Deviation [% of the Span] | ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
Linearity Deviation [% of the span] | ± 0,15; (Turn down 1: 1) |
Hysteresis Deviation [% of the Span] | ± 0,15; (Turn down 1: 1) |
Long-Term Stability [% of the Span] | ± 0,1; (Turn down 1: 1; per year) |
Temperature Monitoring |
Accuracy [K] | ± 2.5 K + (0.045 x (Ambient Temperature - medium temperature)) |
Repeatability [K] | ± 0,2 |
Resolution [K] | 0.2 |
Reaction Times |
Damping for the Analog Output dAA [s] | 0 - 4 |
3-Wire |
Step Response Time Analog Output [ms] | 30 |
3-Wire |
Step Response Time Analog Output [ms] | 7 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | <10 /<25; (DIN EN 60751 water;>0,9 m/s) |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor ED2: Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A) |
SIO Mode | No |
Required Master Port Class | A; (when pin 2 not connected: B) |
Minimum Process Cycle Time [ms] | 4.5 |
IO-Link Resolution Pressure [bar] | 0.005 |
IO-Link Resolution Temperature [K] | 0.2 |
IO-Link Functions (Acyclical) | Application specific tag; internal temperature |
Operating Conditions |
Ambient Temperature [°C] | -25 - 80 |
Storage Temperature [°C] | -40 - 100 |
Protection | |
MTTF [Years] | 322 |
Mechanical Data |
Weight [g] | 306.1 |
Material | Stainless steel (1.4404 / 316L); PTFE; FKM |
Materials (Wetted Parts) | Ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra<0,4 / Rz 4; PEEK; PTFE |
Minimum Pressure Cycles | 100 million |
Tightening Torque [Nm] | 20 |
Process Connection | Threaded connection G 1/2 external thread sealing cone |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |