Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Process Connection | Threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a Process Connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
System | gold-plated contacts |
Media | viscous media and liquids with suspended particles; liquids and gases |
Medium Temperature [°C] | -25 - 150 |
Vacuum Resistance [mbar] | -1000 |
Type of Pressure | Relative pressure; vacuum |
No Dead Space | Yes |
MAWP (for Applications According to CRN) [bar] | 50 |
Electrical Data |
Minimum Insulation Resistance [MΩ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Integrated Watchdog | Yes |
3-Wire |
Operating Voltage [V] | 20 - 30 DC |
Current Consumption [mA] | 3.5 - 21.5 |
Power-on Delay Time [s] | <1 |
3-Wire |
Operating Voltage [V] | 18 - 30 DC |
Current Consumption [mA] | 5 - 45; (430 bei Maximum Laststrom) |
Power-on Delay Time [s] | <0.5 |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; analog signal; IO-Link |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20, invertible; (scalable) |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
3-Wire |
Maximum Load [Ω] | 300 |
3-Wire |
Maximum Voltage Drop Switching Output DC [V] | 2 |
Permanent Current Rating of Switching Output DC [mA] | 100 |
Switching Frequency DC [Hz] | 125 |
Maximum Load [Ω] | (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V) |
Accuracy / Deviations |
Switch Point Accuracy [% of the Span] | ± 0,2; (DIN EN IEC 62828-1; Turn down 1: 1) |
Repeatability [% of the Span] | ± 0,1; (with temperature fluctuations<10 K; Turn down 1: 1) |
Characteristics Deviation [% of the Span] | ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1: 1) |
Linearity Deviation [% of the span] | ± 0,15; (Turn down 1: 1) |
Hysteresis Deviation [% of the Span] | ± 0,15; (Turn down 1: 1) |
Long-Term Stability [% of the Span] | ± 0,1; (Turn down 1: 1; per year) |
Temperature Monitoring |
Accuracy [K] | ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur )) |
Repeatability [K] | ± 0,2 |
Resolution [K] | 0.2 |
Reaction Times |
Damping Process Value dAP [s] | 0 - 99.99 |
Damping for the Analog Output dAA [s] | 0 - 99.99 |
3-Wire |
Step Response Time Analog Output [ms] | 30 |
3-Wire |
Minimum Response Time of Switching Output (dAP) [ms] | 3 |
Step Response Time Analog Output [ms] | 7 |
Temperature Monitoring |
Dynamic Response T05 / T09 [s] | <35 /<135; (DIN EN 60751 water ;>0,9 m/s) |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A) |
SIO Mode | Yes |
Required Master Port Class | A |
Minimum Process Cycle Time [ms] | 5.6 |
IO-Link Resolution Pressure [bar] | 0.0005 |
IO-Link Resolution Temperature [K] | 0.2 |
IO-Link Functions (Acyclical) | Application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter |
Operating Conditions |
Ambient Temperature [°C] | -25 - 80 |
Storage Temperature [°C] | -40 - 100 |
Protection | |
MTTF [Years] | 214 |
Mechanical Data |
Weight [g] | 385.2 |
Material | Stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (Wetted Parts) | Ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra<0,4 / Rz 4; PTFE |
Minimum Pressure Cycles | 100 million |
Tightening Torque [Nm] | 20 |
Process Connection | Threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a Process Connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
Display Unit | Bar; psi; MPa |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |