Product Characteristics |
Type of Light | Red light |
Laser Protection Class | 1 |
Housing | Rectangular |
Electrical Data |
Operating Voltage [V] | 10 - 30 DC; (cULus - Class 2 source required) |
Current Consumption [mA] | <30 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | <0.3 |
Type of Light | Red light |
Wave Length [nm] | 630 |
Typ. lifetime [h] | 50000 |
Inputs / Outputs |
Number of Inputs and Outputs | - Number of Digital Inputs: 1
- Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
Inputs |
Inputs | Laser On/ Off |
Number of Digital Inputs | 1 |
Outputs |
Total Number of Outputs | 2 |
Electrical Design | PNP/NPN; (configurable) |
Number of Digital Outputs | 1 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.2 |
Permanent Current Rating of Switching Output DC [mA] | 100 |
Switching Frequency DC [Hz] | 150 |
Number of Analog Outputs | 1 |
Analog Current Output [mA] | 4 - 20; (IEC61131-2) |
Maximum Load [Ω] | 500 |
Analog Voltage Output [V] | 0 - 10; (IEC 61131-2) |
Minimum Load Resistance [Ω] | 5000 |
Short-Circuit Protection | Yes |
Overload Protection | Yes |
Monitoring Range |
Range adjustable | Yes |
Maximum light spot diameter [mm] | 1 |
Light spot dimensions refer to | At maximum range |
Measuring/Setting Range |
Measuring Range [m] | 0.05 - 0.5; (6 - 90% remission) |
Accuracy / Deviations |
Temperature compensation | Yes |
Linearity error of analog output [%] | ±0,22 |
Notes on the Accuracy / Deviation | The indicated values are reached after a warm-up time of 20 minutes. |
Measuring range (50 - 300 mm) |
Repeatability [mm] | 0.3 |
Resolution [mm] | 0,3 |
Measuring range (300 - 500 mm) |
Repeatability [mm] | 1 |
Resolution [mm] | 0,5 |
Software / Programming |
Parameter Setting | Hysteresis / window / 2-point; Switch-on and switch-off delay; switch-on operations; Teach function; filter; light-on/dark-on mode; laser switch-off; Type of Operation |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Measuring and Switching Sensor, 1 channel, Identification and Diagnosis, Sensor Control, Teach two value, Locator, ProductURI |
SIO Mode | Yes |
Required Master Port Class | A |
Minimum Process Cycle Time [ms] | 3.2 |
IO-Link Functions (Acyclical) | Application specific tag; operating hours counter |
Operating Conditions |
Ambient Temperature [°C] | 0 - 60 |
Storage Temperature [°C] | -10 - 65 |
Protection | |
Laser Protection Class | 1 |
MTTF [Years] | 552 |
Mechanical Data |
Weight [g] | 127.3 |
Housing | Rectangular |
Dimensions [mm] | 51 x 51 x 17 |
Material | Housing: diecast zinc; front lens: plastics |
Tightening Torque [Nm] | 5 |
Teach function | Yes |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |