Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 4 |
Factory Setting | 2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils |
Probe Length L [mm] | 472 |
Media | Hydrous coolants; oils; oil-based media; water; media similar to water |
Dielectric Constant of the Medium | >2 |
Cannot be Used for | Extremely conductive media; adhering media; granulates; bulk material; acids; alkali |
Tank Pressure [bar] | 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) |
Coolants |
Medium Temperature [°C] | 0 - 35; (with climate tube E43101 35 - 60 °C) |
Oil |
Medium Temperature [°C] | 0 - 70 |
Medium Temperature Short Time [°C] | 0 - 90; (<1 h) |
Water |
Medium Temperature [°C] | 0 - 35; (with climate tube E43101 35 - 60 °C) |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC |
Current Consumption [mA] | <50 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | <3 |
Measuring Principle | Capacitive |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 4 |
Outputs |
Total Number of Outputs | 4 |
Output Signal | Switching signal; IO-Link |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 4 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 200 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Thermal, pulsed |
Overload Protection | Yes |
Measuring/Setting Range |
Factory Setting | 2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils |
Probe Length L [mm] | 472 |
Active Range A [mm] | 390 |
Inactive Range I1 / I2 [mm] | 60 / 22 |
Setting Range |
Set Point SP [mm] | 35 - 390 |
Reset Point rP [mm] | 30 - 385 |
In Steps of [mm] | 5 |
Reference Point OP [mm] | 139 - 163 - 188 - 212 - 236 - 261 - 285 - 310 - 334 - 358 - 383 - 407 - OFF |
Hysteresis, OP [mm] | 3 |
Temperature Monitoring |
Measuring Range [°C] | -20 - 90 |
Set point SP [°C] | -19.5 - 90 |
Reset point rP [°C] | -20 - 89.5 |
In steps of [°C] | 0.5 |
Resolution of switching output [K] | 0.5 |
Accuracy / Deviations |
Measuring Error [% of the Final Value] | ± 5 |
Repeatability | ± 2 |
Resolution [mm] | 5 |
Temperature Monitoring |
Switch point accuracy [K] | ± 1,5 |
Resolution [K] | 0.5 |
Dynamic response T09 [s] | 90 |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display Unit; process value assignment |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO Mode | Yes |
Required Master Port Class | A |
Process Data Analog | 4 |
Process Data Binary | 4 |
Minimum Process Cycle Time [ms] | 4.5 |
Operating Conditions |
Ambient Temperature [°C] | 0 - 60 |
Storage Temperature [°C] | -25 - 80 |
Protection | IP 67 |
MTTF [Years] | 195 |
Mechanical Data |
Weight [g] | 372.95 |
Dimensions [mm] | Dia. 16 |
Material | Stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PP; PA; TPV |
Materials (Wetted Parts) | PP |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A |