Generator |
Rated maximum continuous power capacity (LP) | 22,000 Watts |
Rated maximum continuous power capacity (NG) | 19,500 Watts |
Rated voltage | 240 |
Rated maximum continuous load current – 240 volts (LP / NG) | 91.7 / 81.3 |
Total Harmonic Distortion | Less than 5% |
Main line circuit breaker | 100 amp |
Phase | 1 |
Number of rotor poles | 2 |
Rated AC frequency | 60Hz |
Power Factor | 1.0 |
Unit weight (lb / kg) | 466 / 127.3 |
Dimensions (L x W x H) in / cm | 48 x 25 x 29 / 121.9 x 63.5 x 73.7 |
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load | 67 |
Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode | 57 |
Engine |
Engine type | GENERAC G-Force 1000 Series |
Number of cylinders | 2 |
Displacement | 999 cc |
Cylinder block | Aluminum w/ cast iron sleeve |
Valve arrangement | Overhead valve |
Ignition system | Solid-state w/ magneto |
Governor system | Electronic |
Compression ratio | 9.5:1 |
Starter | 12 VDC |
Oil capacity including filter | Approx. 1.9 qt/1.9 L |
Operating rpm | 3,600 |
Controls |
Two-line plain text multilingual LCD | Simple user interface for ease of operation |
Mode buttons: |
AUTO | Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser. |
OFF | Stops unit. Power is removed. Control and charger still operate |
MANUAL | Start with starter control, unit stays on. If utility fails, transfer to load takes place. |
Ready to Run/Maintenance messages | Standard |
Engine run hours indication | Standard |
Programmable start delay between 2–1500 seconds | Standard (programmable by dealer only) |
Utility Voltage Loss/Return to Utility adjustable (brownout setting) | From 140-171 V / 190-216 V |
Future Set Capable Exerciser/Exercise Set Error warning | Standard |
Run/Alarm/Maintenance logs | 50 events each |
Engine start sequence | Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) |
Starter lock-out | Starter cannot re-engage until five seconds after engine has stopped |
Smart Battery Charger | Standard |
Charger Fault/Missing AC warning | Standard |
Low Battery/Battery Problem Protection and Battery Condition indication | Standard |
Automatic Voltage Regulation with Over and Under Voltage Protection | Standard |
Under-Frequency/Overload/Stepper Overcurrent Protection | Standard |
Safety Fused/Fuse Problem Protection | Standard |
Automatic Low Oil Pressure/High Oil Temperature Shutdown | Standard |
Overcrank/Overspeed ( at 72 Hz)/rpm Sense Loss Shutdown | Standard |
High Engine Temperature Shutdown | Standard |
Internal Fault/Incorrect Wiring protection | Standard |
Common external fault capability | Standard |
Field upgradable firmware | Standard |