Electrical |
AC Volts (40 to 500 Hz) | - Range: 6, 60, 600 V
- Resolution: 0.001, 0.01, 0.1 V
- Accuracy: 1.0% + 3
|
DC Volts | - Range: 6, 60, 600 V
- Resolution: 0.001, 0.01, 0.1 V
- Accuracy: 0.5% + 3
|
AC Millivolts | - Range: 600 mV
- Resolution: 0.1 mV
- Accuracy: 3.0% + 3
|
Diode Test | - Range: 2 V
- Resolution: 0.001 V
- Accuracy: 10%
|
Resistance (Ohms) | - Range: 400 Ω, 4, 40, 400 kΩ, 4, 40 MΩ
- Resolution: 0.1 Ω, 0.001, 0.01, 0.1 kΩ, 0.001, 0.01 MΩ
- Accuracy: 0.5% + 3, 0.5% + 3, 0.5% + 3, 0.5% + 3, 0.5% + 3, 1.5% + 3
|
Capacitance | - Range: 50, 500 nF, 5, 50, 500, 1000 µF
- Resolution: 0.01, 0.1 nF, 0.001, 0.01, 0.1, 1µF
- Accuracy: 2% + 5, 2% + 5, 5% + 5, 5% + 5, 5% + 5, 5% + 5
|
Frequency (10 Hz to 100 kHz) | - Range: 50, 500 Hz, 5, 50, 100 kHz
- Resolution: 0.01, 0.1 Hz, 0.001, 0.01, 0.1 kHz
- Accuracy: 0.1% + 3
|
Duty Cycle | - Range: 0.1 to 99.9%
- Resolution: 0.1%
- Accuracy: 1% typical
|
AC Current (40 to 200 Hz) | - Range: 4, 10 A
- Resolution: 0.001, 0.01 A
- Accuracy: 1.5% + 3
|
DC Current (40 to 200 Hz) | - Range: 4, 10 A
- Resolution: 0.001, 0.01 A
- Accuracy: 1.5% + 3
|
Backlight | Accuracy: Yes |
AC Volts | - Overload protection: 600 V
- Input impedance (nominal): >10 MΩ, <100 pF
- Common mode rejection ratio: >60 dB at DC, 50 or 60 Hz
|
AC Millivolts | - Overload protection: 600 mV
- Input impedance (nominal): >1 M, <100 pF
- Common mode rejection ratio: >80 dB at 50 or 60 Hz
|
DC Volts | - Overload protection: 600 V
- Input impedance (nominal): >10 MΩ, <100 pF
- Common mode rejection ratio: >100 dB at DC, 50 or 60 Hz
- Normal mode rejection ratio: >45 dB at 50 or 60 Hz
|
General |
Maximum Voltage Between Any Terminal and Earth Ground | 600 V |
Display (LCD) | 6000 counts, updates 3/sec |
Battery Type | 2 x AAA Batteries, NEDA 24A, IEC LR03 |
Battery Life | 200 hours minimum |
Temperature | - Operating: 32 to 104°F (0 to 40°C)
- Storage: -22 to 140°F (-30 to 60°C)
|
Operating Humidity: Non-condensing when <50°F (<10°C) | - ≤90% at 50 to 86°F (10 to 30°C)
- ≤75% at 50 to 104°F (30 to 40°C)
|
Operating Humidity, 40 MΩ Range | - ≤80% at 50 to 86°F (10 to 30°C)
- ≤70% at 50 to 104°F (30 to 40°C)
|
Altitude | - Operating: 6561.7' (2000 m)
- Storage: 39,370.1' (12,000 m)
|
Temperature Coefficient | 0.1 X (specified accuracy)/°C (<18 or >28°C) |
Fuse Protection for Current Inputs | 11 A, 1000 V fast fuse |
Dimensions | 5.6 x 2.7 x 1.1" (142 x 69 x 28 mm) |
Weight | 0.44 lb (200 g) |
IP Rating | IEC 60529: IP40 |