Visual IR Thermometer |
Built-In Visual Camera | Yes, get the context of visible light details in images |
Infrared Heat Map and Visual Image Blending | Yes, five blending modes on camera and continuous blending in SmartView software |
Alignment Options | - Near: <9" (23 cm) from target
- Far: >9" (23 cm) from target
|
Field of View | 28° x 28° - the tight field of view lets see more detail in target |
Temperature Measurement Range | 14 to 482°F (-10 to 250°C) |
Focus System | Focus free |
Temperature Measurement Area | Center measurement box on screen shows the exact area the measurement is based on |
File Format | .bmp or .is2. (the .is2 is editable in SmartView software) |
Storage Medium | 4GB micro-SD card that stores up to 9,999 images |
Palettes | - 6 on the unit (Ironbow VT, Hot Metal, Greyscale Inverted, Greyscale, High Contrast VT, Rainbow)
- 4 additional in SmartView Software (Blue Red, High Contrast, Amber, Amber Inverted)
- Palette on .is2 images can be changed in SmartView software
|
Insulation Resistance Tester |
Maximum Voltage applied to any Terminal | 600 V AC rms or DC |
Temperature | - Operating: -4 to 131°F (-20 to 55°C)
- Storage: -40 to 140°F (-40 to 60°C)
|
Temperature Coefficient | 0.05 x (specified accuracy) per°C for temperatures <64°F or >82°F (<18°C or >28°C) |
Vibration | Random, 2 g, 5 to 500 Hz per MIL-PRF-28800F, Class 2 instrument |
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
Electromagnetic Compatibility | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) |
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
Battery | 4 x AA batteries (NEDA 15A or IEC LR6) |
Dimensions | 1.97 x 3.94 x 8.00" (5.0 x 10.0 x 20.3 cm) |
Weight | 1.2 lb (550 g) |
IP Rating | IP40 |