Alderon, SP31-018, Suspension Probe Control Panel, Three Phase Simplex, 208/230/460VAC, 20.0-25.0 FLA, Type 4X, Motor Protective Switch, (4) 20' Probes (Reference, Off, Start, High Level Alarm)
Features:
- Enclosure - Thermoplastic, Type 4X
- HOA Switch - Automatic or manual pump control
- Green Pump Run Indicator
- Fused Control Disconnect (Provides on/off function)
- Alternating Relay (Duplex only)
- Multi-Tap Transformer
- IEC Motor Contactor
- Motor Protective Switch
- Field Wiring Terminal Block
- Terminal Block Field - Wiring label
- Ground Lug
- Suspension Probe Sensors
- Probe Sensors Labeled - For easy field wiring
- Alarm Fuse (Model Specific)
- Alarm Indicator (Model Specific)
- Alarm Buzzer - Loud 100 db warble
- Auto Reset - Horn silence (Model Specific)
- Test/Silence Switches - (Model Specific)
- Industrial Control Panel (UL 508A)
The Suspension Probe Three Phase Simplex control panel is used to operate a pump for water, dewatering, and storm water applications. Comes in 208/230/460VAC, 20 - 25 FLA Ranges, and a Type 4X (outdoor) enclosure. The control panel includes four (4) 20' single point suspension probes, a hand-off-auto (HOA) switch with pump run indicator, and a drain-fill selector switch. The incoming and pump power must match system voltage with conduit connections (required) per local codes. Refer to included electrical schematic for complete wiring and voltage information.
The control panel is operated by the included suspension probes for reference point, pump stop, pump start, and high/low liquid level alarm. As the liquid level rises/recedes activating the pump start probe, the pump will start and continue to run until the pump stop probe is deactivated to complete the pump cycle. If the high/low level probe is activated, the beacon will illuminate and buzzer will annunciate. If the alarm test/silence switch is toggled to "silence" during an alarm condition, it will silence the buzzer while the alarm beacon remains illuminated. The alarm condition will reset when the high/low level probe deactivates and the system will auto rest for the next alarm cycle. Test alarm once a month to ensure system integrity, toggle the alarm test/silence switch to "test", the beacon should illuminate and buzzer should annunciate. Use the drain-fill selector switch to easily convert from a pump down (drain) to pump up (fill) application without having to rewire the suspension probes.
Auxiliary contacts can be included to connect to a building automation system (BAS) or SCADA system and phone dialers for remote notification of an alarm condition and/or pump run event.
For more information, please see Data Sheet and Standard Control Panel Accessories