Alderon, 2000229, VersAlarm 4X, 1-Zone, 4x4x3 PC Enclosure, Type 4X - Outdoor Tank Alarm, 120VAC, Terminal Block
Features:
- (1) Power / Zone Indicator LEDs - Two green LEDs (bottom/middle) illuminate (solid) to indicate the alarm is powered and the left green LED is used as a zone indicator during an alarm condition.
- (2) Alarm LEDs - Four red LEDs illuminate (flashing) during an alarm condition (top, bottom, and top/middle) and low battery (pulse).
- (3) Alarm Buzzer - Annunciates a pulse tone in addition to the visual indication provided by the red alarm and green zone LEDs during an alarm condition. Quick pulse tones indicate low battery.
- (4) Test/Silence Capacitive Touch Button - Press and hold (1-second +) the button to test alarm, silence the buzzer during an alarm condition, or turn off the LEDs (green/red). Place finger in the center of the button, sensor ignores edge touches.
- (5) Power/Alarm LEDs Off - Press and hold the test/silence button for 8-seconds to disable the green power LEDs. Press and hold for 16-seconds to disable the red low battery alarm LEDs. Repeat the process for each to turn back on.
- (6) Incoming Power Wago Connectors - Connect incoming power to the respective Wago connectors (L1 and L2/N), the voltage and included connectors depends on model.
- (7) Auxiliary "Dry" Contacts - Interface with an external device. The contacts (normally open) are rated 120VAC at 0.3A maximum. Quick connect terminals (AUX1).
- (8) Sensor Input - Quick connect terminals (ALM1) for the float switch (signaling device).
- (9) Battery Terminals - Install a 9VDC lithium battery (not included) for battery backup during power outages.
- (10) Pump Terminal Block - Connect incoming pump power, pump connections, and pump switch.
- (11) Enclosure and Mounting Holes - Rated Type 4X (outdoor), includes six mounting holes, lockable latch, and is thermoplastic.
The VersAlarm™ 4X 1-Zone Tank Alarm with included auxiliary contacts is outdoor rated and powered by 120VAC with conduit connections (required). The alarm includes a pump terminal block used to connect incoming pump power, pump connections, and pump switch in the same enclosure with a separate conduit entrance. When powered, the green LEDs (bottom/middle) will illuminate (solid) to indicate the alarm is powered and the included two-level press-and-hold feature can disable LEDs. Install a 9VDC lithium battery (not included) for battery backup during power outages, alarm LEDs and buzzer give two quick pulses every 10-seconds to indicate a low battery. This alarm panel can be used for a wide variety of applications, including but not limited to: septic tanks, sump pits, holding tanks, pump chambers, and water tanks.
The alarm panel is equipped with audible and visual alarm indication, activated by the normally open or normally closed float switch wired to the quick connect terminals. A variety of sensors can be used such as a float switch, pressure switch, or any "dry" type sensor that "closes" during an alarm condition (normally open or normally closed). Use the auxiliary contacts to connect to building automation systems (BAS) and phone dialers. The pump switch activates the pump to turn on and off, with the alarm enclosure used a junction box for wiring.
An alarm condition occurs when the float switch (signaling device) contact is activated, during which the red alarm LEDs will illuminate (flashing) with the left green LED illuminated (solid) for zone alarm indication, buzzer will annunciate with a pulse tone, and auxiliary contacts will activate. The alarm condition will stay on until the float switch is deactivated. Press and hold (1-second +) the test/silence capacitive touch button to silence the buzzer during an alarm condition, the alarm LEDs remain illuminated, flashing. The silence condition will reset when the float switch deactivates and the alarm will auto reset for the next alarm cycle. Test alarm monthly to ensure system integrity.
For more information, please see Data Sheet and Quick Start Quide