| Product Characteristics |
| Process Connection | Threaded connection G 1 Internal thread |
| System | Gold-plated contacts |
| Media | Liquids; oil (viscosity 220 mm² /s at 40° C) |
| Medium Temperature [° C] | -10 - 100 |
| Pressure Rating [bar] | 100 |
| Pressure Rating [MPa] | 10 |
|
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV ; cULus - Class 2 source required) |
| Current Consumption [mA] | < 50 |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | < 3 |
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Switching signal; analog signal; frequency signal; IO-Link |
| Maximum Voltage Drop Switching Output DC [V] | 2 |
| Maximum Current Load per Output [mA] | 150; (200: - 60 ° C; Ambient Temperature; 250: - 40 ° C; Ambient Temperature) |
| Analog Current Output [mA] | 4 - 20 |
| Maximum Load [Ω ] | 500 |
| Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Frequency of the output [Hz] | 0 - 10000 |
| Measuring/Setting Range |
| Frequency at the end point FRP [Hz] | 10 - 10000 |
| In steps of [Hz] | 10 |
| Measuring dynamics | 1: 50 |
| Temperature Monitoring |
| Frequency at the end point FRP [Hz] | 10 - 10000 |
| Accuracy / deviations Flow monitoring |
| Accuracy (in the Measuring Range) | ± 5 % MEW; (Q>1 l/min; 20 - 70 ° C Medium temperature) |
| Repeatability | ± 1 % MEW |
| Temperature Monitoring |
| Temperature Drift | 0,029 ° C / K |
| Accuracy [K] | 3 K (25° C; Q>1 l/min) |
| Reaction Times Flow monitoring |
| Response Time [s] | 0.01 |
| Damping Process Value dAP [s] | 0 - 5 |
| In steps of [s] | 0.1 |
| Damping for the Analog Output dAA [s] | 0 - 5 |
| In steps of [s] | 0.1 |
| Temperature Monitoring |
| Dynamic Response T05 / T09 [s] | T09 = 120 (Q>1 l/min) |
| Software / Programming |
| Parameter Setting | Hysteresis / window; normally open / closed; switching logic; current/frequency output; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color; calibration factor |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Process Data Analog | 2 |
| Process Data Binary | 2 |
| Minimum Process Cycle Time [ms] | 3.2 |
| Operating Conditions |
| Ambient Temperature [° C] | 0 - 60 |
| Storage Temperature [° C] | -15 - 80 |
| Protection | |
| Pressure Equipment Directive | Sound engineering practice |
| Mechanical Data |
| Weight [g] | 1545.3 |
| Material | Stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (Wetted Parts) | Stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Process Connection | Threaded connection G 1 Internal thread |
| Switching Cycles Mechanical | 10 million |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |